Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Heavy-Duty Industrial Pressure Transmitters

PX51/PXM51 Series

Heavy-Duty Industrial Pressure Transmitter | High Pressure and Voltage Output | PX51/PXM51 Series

CE
  • Rugged Thick Film Sensing Element
  • All Stainless Steel Construction
  • Sealed SS Case for Harsh Environments
Pressure Transducers - View related products

Description

OMEGA’s PX51 Series consists of high-accuracy, low-cost pressure transmitters. Their sealed, all stainless steel construction makes them suitable for the harshest environments. They are available in gage, absolute, or sealed gage models. Ten feet of PVC insulated shielded cable is standard, or a twist-lock style connector is also available. A wide selection of amplified voltage and current outputs makes the PX51 a truly versatile family of industrial transmitters.

Consult sales for units available with Inconel construction.



SPECIFICATIONS
Output/Excitation Voltages
    4 to 20 mA or 0 to 5 Vdc Outputs: 10 to 32 Vdc max
    0 to 10 Vdc Outputs: 16 to 32 Vdc max
Accuracy (Combined Linearity, Hysteresis and Repeatability): ±0.25% FS
Minimum Resistance Between Transducer Body and Any Wire: 100 MΩ @ 50 Vdc
With Potentiometers Zero and Span Adjustable: ±10% FS
Without Potentiometers: Zero Set ±5.0% max, Span Set ±1.0% max
Compensated Temperature Range: 16 to 71°C (60 to 160°F)
Zero Shift: 0.005%FS/°F
Span Shift: 0.003% Reading/°F
Operating Temperature: -40 to 104°C (-40 to 220°F)
Wetted Material: 17-4 Stainless Steel
EMC Compliant: Up to 30 m (98.4') of cable
    EN 61326-1:2006
    EN 61326-2-3:2006 Industrial levels
Electrical Connection (for PTIH-10-6P twist-lock connector): PT06F10-6S (sold separately)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
PX51, examples of IMPERIAL Model numbers
Absolute Pressure (All Ranges Available in Absolute Pressure)
PX51C0-015AI
Consult Sales  
Availability: 
 
 
0 to 15 psi range, 4-20 mA output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-030AINP
Consult Sales  
Availability: 
 
 
0 to 30 psi range, 4-20 mA output, 1/4-18 NPT-M pressure port,cable connection, no potentiometers
PX51C0-100AI
Consult Sales  
Availability: 
 
 
0 to 100 psi range, 4-20 mA output, 1/4-18 NPT-M pressure port,cable connection
PX51S0-10KAI
Consult Sales  
Availability: 
 
 
0 to 10,000 psi range, 4-20 mA output,1/4 HP tube fitting pressure port, cable connection
PX51S0-15KAI
Consult Sales  
Availability: 
 
 
0 to 15,000 psi range, 4-20 mA output,1/4 HP tube fitting pressure port, cable connection
PX51S0-30KAINP
Consult Sales  
Availability: 
 
 
0 to 30,000 psi range, 4-20 mA output,1/4 HP tube fitting pressure port, cable connection, no potentiometers
PX51C0-015A5V
Consult Sales  
Availability: 
 
 
0 to 15 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-075A5V
Consult Sales  
Availability: 
 
 
0 to 75 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-750A5VNP
Consult Sales  
Availability: 
 
 
0 to 750 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers
PX51S0-10KA5V
Consult Sales  
Availability: 
 
 
0 to 10,000 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51S0-20KA5V
Consult Sales  
Availability: 
 
 
0 to 20,000 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51S0-30KA5VNP
Consult Sales  
Availability: 
 
 
0 to 30,000 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers
PX51C0-010A10VNP
Consult Sales  
Availability: 
 
 
0 to 10 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers
PX51C0-025A10V
Consult Sales  
Availability: 
 
 
0 to 25 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-500A10V
Consult Sales  
Availability: 
 
 
0 to 500 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51S0-15KA10VNP
Consult Sales  
Availability: 
 
 
0 to 15,000 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers
PX51S0-20KA10V
Consult Sales  
Availability: 
 
 
0 to 20,000 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51S0-30KA10V
Consult Sales  
Availability: 
 
 
0 to 30,000 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection
Gage Pressure (All Ranges Available in Gage Pressure)
PX51C0-015GI
Consult Sales  
Availability: 
 
 
0 to 15 psi range, 4-20 mA output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-020GI
Consult Sales  
Availability: 
 
 
0 to 20 psi range, 4-20 mA output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-3.5KGINP
Consult Sales  
Availability: 
 
 
0 to 3500 psi range, 4-20 mA output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers
PX51S0-15KGI
Consult Sales  
Availability: 
 
 
0 to 15,000 psi range, 4-20 mA output, 1/4 HP tube fitting pressure port, cable connection
PX51S0-20KGINP
Consult Sales  
Availability: 
 
 
0 to 20,000 psi range, 4-20 mA output, 1/4 HP tube fitting pressure port, cable connection, no potentiometers
PX51S0-30KGI
Consult Sales  
Availability: 
 
 
0 to 30,000 psi range, 4-20 mA output, 1/4 HP tube fitting pressure port, cable connection
PX51C0-025G5V
Consult Sales  
Availability: 
 
 
0 to 25 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-050G5VNP
Consult Sales  
Availability: 
 
 
0 to 50 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers
PX51C0-500G5V
Consult Sales  
Availability: 
 
 
0 to 500 psi range, 0 to 5 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51S0-15KG5V
Consult Sales  
Availability: 
 
 
0 to 15,000 psi range, 0 to 5 Vdc output, 1/4 HP tube fitting pressure port, cable connection
PX51S0-20KG5VNP
Consult Sales  
Availability: 
 
 
0 to 20,000 psi range, 0 to 5 Vdc output, 1/4 HP tube fitting pressure port, cable connection, no potentiometers
PX51S0-30KG5V
Consult Sales  
Availability: 
 
 
0 to 30,000 psi range, 0 to 5 Vdc output, 1/4 HP tube fitting pressure port, cable connection
PX51C0-010G10VNP
Consult Sales  
Availability: 
 
 
0 to 10 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers
PX51C0-100G10V
Consult Sales  
Availability: 
 
 
0 to 100 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51C0-2.5KG10V
Consult Sales  
Availability: 
 
 
0 to 2500 psi range, 0 to 10 Vdc output, 1/4-18 NPT-M pressure port, cable connection
PX51S0-15KG10V
Consult Sales  
Availability: 
 
 
0 to 15,000 psi range, 0 to 10 Vdc output, 1/4 HP tube fitting pressure port, cable connection
PX51S0-20KG10VNP
Consult Sales  
Availability: 
 
 
0 to 20,000 psi range, 0 to 10 Vdc output, 1/4 HP tube fitting pressure port, cable connection, no potentiometers
PX51S0-30KG10V
Consult Sales  
Availability: 
 
 
0 to 30,000 psi range, 0 to 10 Vdc output, 1/4 HP tube fitting pressure port, cable connection
All amounts shown in AUD
Note: All models come complete with 5-point NIST traceable calibration.
To order sealed gage pressure models, replace “G” in model number with “SG” (no extra charge).
To order Standard configurations including Potentiometers, no suffix required. For “No Potentiometers”, add “NP” suffix.


Ordering Example: (1) PX51C0-3.5KGINP 0 to 3500 psi range, 4-20 mA output, 1/4-18 NPT-M pressure port, cable connection, no potentiometers, AUD1,360.00

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Series select from:
PX51 for Imperial
PXM51 for Metric

(2) Pressure Port select from:
C for Imperial 1/4-18 NPT-M
D for Imperial 1/4-18 NPT-F
T for Imperial Dual 1/2-14 NPT external 1/4-18 NPT internal
K for Imperial 7/16-20 UNF-F
J for Imperial 7/16-20 UNF-M
S for Imperial 1/4 HP Tube Fitting (>=10000 psi ranges)
MA for Metric G1/8B Male
MB for Metric G1/8B Female
MC for Metric G1/4B Male
MD for Metric G1/4BFemale

(3) Electrical Connection select from:
0 for 3 m (10') pigtail cable standard with 1/2 NPT conduit
1 for PTIH-10-6P twist-lock connector
5 for M12 connector
6 for mini-DIN connector
GW for Submersible waterproof cable with 1/2 NPT conduit

(4) Range select from:
010 for Imperial pressure 0 to 10 psi
015 for Imperial pressure 0 to 15 psi
020 for Imperial pressure 0 to 20 psi
025 for Imperial pressure 0 to 25 psi
030 for Imperial pressure 0 to 30 psi
050 for Imperial pressure 0 to 50 psi
075 for Imperial pressure 0 to 75 psi
100 for Imperial pressure 0 to 100 psi
200 for Imperial pressure 0 to 200 psi
300 for Imperial pressure 0 to 300 psi
500 for Imperial pressure 0 to 500 psi
750 for Imperial pressure 0 to 750 psi
1K for Imperial pressure 0 to 1000 psi
1.5K for Imperial pressure 0 to 1500 psi
2K for Imperial pressure 0 to 2000 psi
3.5K for Imperial pressure 0 to 3500 psi
5K for Imperial pressure 0 to 5000 psi
7.5K for Imperial pressure 0 to 750 psi
10K for Imperial pressure 0 to 10000 psi (Supplied with type "S" pressure port and 1/4" HP tube fitting)
15K for Imperial pressure 0 to 15000 psi (Supplied with type "S" pressure port and 1/4" HP tube fitting)
20K for Imperial pressure 0 to 20000 psi (Supplied with type "S" pressure port and 1/4" HP tube fitting)
30K for Imperial pressure 0 to 30000 psi (Supplied with type "S" pressure port and 1/4" HP tube fitting)
0.7 for Metric pressure 0 to 0.7 bar
001 for Metric pressure for 0 to 1 bar
1.60 for Metric pressure 0 to 1.60 bar
2.50 for Metric pressure 0 to 2.50 bar
004 for Metric pressure 0 to 4 bar
006 for Metric pressure 0 to 6 bar
010 for Metric pressure 0 to 10 bar
016 for Metric pressure 0 to 16 bar
025 for Metric pressure 0 to 25 bar
040 for Metric pressure 0 to 40 bar
060 for Metric pressure 0 to 60 bar
100 for Metric pressure 0 to 100 bar
160 for Metric pressure 0 to 160 bar
250 for Metric pressure 0 to 250 bar
400 for Metric pressure 0 to 400 bar

(5) Units select from:
A for Absolute pressure
G for Gage pressure
SG for Sealed Gage pressure

(6) Output select from:
I for 4 to 20 mA output
5V for 0 to 5 Vdc output
10V for 0 to 10 Vdc output

(7) Options select from:
Nothing(leave field blank) for None
NP for No Potentiometers
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.