The FDT-30 series has been discontinued. Please see the FDT-40 as a possible alternative or contact our Flow Engineering department.
The FDT-30 Series provides easy and low cost installation by clamping to the outside of existing piping
systems. Non-invasive transit time system allows solids to pass through the pipe with no affect on the
meter. Y-strainers or filtering devices are not needed. Greater accuracy can be attained in applications
consisting of entrained gases. The FDT-30 Series will automatically correct displayed flow rates and
electronic outputs. Direct interface is provided to data collection systems via 4 to 20 mA output and
either TTL-pulse or simulated turbine meter outputs that are proportional to fluid flow rate. Designed
to replace mechanical flowmeters in applications where liquid conditions tend to damage or impede
mechanical flow meter operation. No maintenance is required. The FDT-30 Series can be used on applications
such as well water and other liquids with moderate amounts of suspended solids or aeration.
FDT-30 Series is housed in an enclosure suitable for outdoor mounting. Integral mount transducers are
available for pipes 50 mm (2") and smaller.
SPECIFICATIONs Liquid Types: Most clean liquids, or liquids containing moderate amounts of suspended solids Power: 11.4 to 30 Vdc @ 0.25 A Velocity: 0.03 to 12.4 MPS (0.1 to 40 FPS) 4 to 20 mA Output (Standard): 12-bit resolution; source power; 5V max insertion loss; 900 Ω
max loop impedance; can share ground common with power supply-isolated from piping system Turbine Frequency Output (TTL Pulse): Switch selectable; non-ground referenced AC, ground referenced squarewave; 100 mV pp min/5 Vdc amplitude; 0 to 1 kHz range; 50% ±10% duty cycle Display: 2 line x 8 character LCD alternates between rate and total in 10 second intervals Top Row: 18 mm (0.7"), 7-segment Bottom Row: 9 mm (0.35"), 14-segment Rate: 8 digits max Totalizer: 8 digits max; exponential multipliers from -1 to +6 Units: Feet, gallons, ft³, million-gal, barrels (liquid and oil), acre-feet, lbs, meters, m³, liters, million-liters, kg; rates programmable for per: sec, min, hr, or day Operating Ambient: -40 to 85°C (-40 to 185°F) Enclosure: NEMA 3 ABS, PVC and Ultem, brass or SS hardware Dimensions: 75 W x 150 L x 63 mm D (3 x 6 x 2.5") Transducer Type: Clamp-on for pipe mount; time of flight ultrasonic Accuracy: ±1% rdg @ rates > 0.3 MPS (1 FPS); ±0.003 MPS (0.01 FPS) @ rates < 0.3 MPS (1 FPS) Repeatability: ±0.5% rdg Response Time: 0.3 to 30 sec, adjustable Protection: Reverse polarity, surge suppression Pipe Sizes: 12 to 50 mm (0.5 to 2") Pipe Materials: Carbon steel, stainless steel, copper and plastic
† All amounts shown in AUD Note: Comes complete with acoustic couplant and operator's manual.
(1)
Range LPM (GPM) select from: 31 for 2 to 100 (0.5 to 25) 32 for 4 to 200 (1 to 55) 33 for 8 to 375 (2 to 100) 34 for 15 to 570 (4 to 150) 35 for 18 to 830 (5 to 220) 36 for 30 to 1500 (8 to 400)
(2)
Additional Option select from: Nothing(leave field blank) for ANSI carbon steel/stainless steel pipe -C for Copper pipe applications -T for Plastic tubing applications
Note: All combinations may not be valid, check spec sheet for valid part numbers.