Portable Data Logger with 16 or 32 Universal Inputs Plus 2 High Voltages, 4 Pulse and 8 DigitalEvent/State Inputs - Discontinued

OM-SQ2040-2F16

Portable Data Logger with 16 or 32 Universal Inputs Plus 2 High
Voltages, 4 Pulse and 8 DigitalEvent/State Inputs | OM-SQ2040-2F16

CE
  • 16 True Differential or 32 Single-Ended Universal Analog Inputs for Voltage, Current or Resistance Measurements - Plus 2 High Voltages, 4 Pulse and 8 Digital Event/State Inputs
  • Analog Inputs Can Be Used with Thermistors, Thermocouples, 2, 3 or 4-Wire RTD Temperature Sensors and 4 to 20 mA Signals
  • User Selectable Logging Rates of Up to 100 Hz on Up to 4 Channels
  • Download of Internal Data to Removable MMC/SD (Multi Media Card/Secure Digital) Memory
  • Large Non-Volatile Internal Memory - Data Retention is Virtually Indefinite
  • Ethernet, Wi-FI (On the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 Communication Ports
  • Ethernet, USB and RS-232 Communication Ports
  • Sensor Power and FET Alarm Outputs For Use With External Devices
  • Easy Access to Information Using the 2 Line, 20 Character LCD and Push Button Panel
  • Calculated Channels Derived from Real Channels Using Advanced Mathematical Functions

Description

This product line has been discontinued, a replacement will soon be introduced into the Omega catalog. As a potential alternate available now, please see OM-CP-OCTPRO as an alternative


Please check out Newest Released 24 plus channel Ethernet Data Logger OM-240 Series for more advanced features.

The OM-SQ2040 Series combines a higher channel count with the same high performance, comprehensive features and universal inputs as the OM-SQ2020 in a neat compact and portable instrument. Using multiple 24-bit analog to digital convertors, twin processors and removable memory options provide great flexibility to handle a wide range of complex and demanding multichannel applications.

The OM-SQ2040 series are the ideal data loggers for industrial, scientific research and quality assurance applications. The OM-SQ2040 provides standalone data acquisition, advanced networked solutions and data analysis straight out-of-the-box.

Input Connections:
The OM-SQ2040-2F16 data logger has two analog to digital converters (A/D’s) which increases logging flexibility over the OM-2020-1F8 model. The first corresponds to inputs on blocks A, B, C and D and the second corresponds to inputs on blocks G, H, J and K. Each connection block will accept up to 2 differential inputs or up to 4 single-ended inputs (it is not possible to mix single ended and differential inputs on a block). The OM-SQ2040-4F16 data logger has four analog to digital converters (A/D’s) which increases logging flexibility over the other OM-SQ2020 and OM-SQ2040 models. The first corresponds to inputs on blocks A and B, the second corresponds to inputs on blocks C and D, the third corresponds to inputs on blocks G and H and the fourth corresponds to inputs on blocks J and K. Each connection block will accept up to 2 differential inputs or up to 4 single— ended inputs (it is not possible to mix single-ended and differential inputs on a block).

Concurrent Sampling:
The OM-SQ2040 series uses |multiple analog to digital converters that enables true concurrent sampling and logging. This allows the user to configure up to 4 channels to log at a rate of 100 Hz while retaining different sample speeds on other channels. This makes the OM-SQ2040 ideal for measuring dynamic parameters that change at different rates such as temperature and pressure.

Communications:
Ethernet, Wi-Fi (on the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 serial ports are built-in. This allows quick connection to either a PC based TCP/IP network, a wireless to PC connection or to a modem for remote data downloading. This flexibility enables global data access and retrieval as well as complete system integration of the OM-SQ2040 series into complex and critical applications.

Multiple Configurations Stored in the Logger:
Up to six logger configurations (channel type, names, logging speeds, triggers, etc.), together with the current configuration, can be held in the logger’s internal memory. Additional configuration settings can also be loaded from the external MMC/SD memory card. This allows the operator to quickly and easily switch between logger configurations without the need for a PC.

Comprehensive Software Configuration
The OM-SQ-SOFT software (supplied with the OM-SQ2040 series data loggers) allows logger configuration, data download and data export while giving the user full control over the OM-SQ2040. The optional OM-SQ-SOFT-PLUS software gives the user access to many advanced data analysis and data archiving/transfer features. The optional OM-SQ-SOFT-PLUS software lets you quickly and easily analyze the data from your OM-SQ2040 data logger in a familiar Explorer style interface. Data can be displayed with 2 different auto scaling Y-axis. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get astatistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels.

The OM-SQ-SOFT-PLUS software also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data.

Specifications
ANALOG INPUTS
Accuracy:
See table on PDF
Common Mode Rejection: 100 dB
Input Impedance: >1MÙ
Linearity: 0.015%
Series Mode Line Rejection: 50/60 Hz 100 dB
Analog Input Connections: Detachable screw terminal blocks

ANALOG - DIGITAL CONVERSION
Type:
Sigma-Delta
Resolution: 24-bit
Sampling Rate: Up to 10, 20* or 100* readings per second per ADC. * With mains rejection off

ALARM OUTPUTS
4 x open drain FET (18 V 0.1 A)
Digital I/O Connections: DB25F connector

CALCULATED CHANNELS
Up to 16 virtual channels derived from physical input channels

RESOLUTION
Up to 6 significant digits

PROGRAMMING/LOGGER SETUP
OM-SQ-SOFT or OM-SQ-SOFT-PLUS software; software compatible with WIN XP/VISTA
(32-bit & 64-bit)/7 (32-bit & 64-bit)

COMMUNICATION
Standard:
RS-232 (automatic baud rate selection to 115200 baud) Ethernet 10/100 base TCP/IP USB 1.1 and 2.0 compatible
Wireless Ethernet: (Wi-Fi); 802.11b, 2.4GHz, 1 to 14 channels Security: Open, WEP (64 or 128bi encryption), WPA or PA2/802.11i Network: Infrastructure only with specified SSID (external power pack required for Wi-Fi connection)
External Options: GSM, WIFI and PSTN Modems

POWER SUPPLY
Internal:
6 "AA" alkaline batteries (included)
External: 10 to 18 Vdc reverse polarity and over-voltage protected

POWER CONSUMPTION @ 9V
Sleep Mode:
600 µA Logging: 40 to 130 mA

DISPLAY AND KEYPAD
2 line x 20 character LCD display; battery state and external power indicator; keypad lock
Navigate To: Arm/disarm/pause/ continue; meter any channel or alarm; select from up to 6 x pre-stored setups; status/diagnostics/memory/ time and date; download to MMC/SD

OPERATING ENVIRONMENT
Temperature:
-30 to 65°C (-22 to 149°F)
Humidity: 90% at 40°C non-condensing

GENERAL
Power Output for External Device:

Regulated 5 Vdc at 50 mA or logger supply voltage at 100 mA
Time and Date: Built-in clock in 3 formats
Scaling Data: Displays readings in preferred engineering units
Internal Memory: 16 MB (Up to 1,800,000 readings)
External Memory: Up to 1 GB - removable MMC/SD
(for transferring internal memory and storing setups only)
Dimensions: 175 H x 235 W x 95 mm D (6.9 x 9.3 x 3.7")
Weight: Approx. 1.2 kg (2.6 lb)
Enclosure Material: ABS
Memory Modes (Internal Only): Stop when full or overwrite
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
OM-SQ2040-2F16
Consult Sales  
Availability: 
 
 
Portable data logger with 2 fast channels
  
OM-SQ2040-4F16
Consult Sales  
Availability: 
 
 
Portable data logger with 4 fast channels
  
OM-SQ2040-2F16-WIFI
Consult Sales  
Availability: 
 
 
Portable data logger with 2 fast channels and integrated Wi-Fi networking
  
OM-SQ2040-4F16-WIFI
Consult Sales  
Availability: 
 
 
Portable data logger with 4 fast channels and integrated Wi-Fi networking
Accessories
  
OM-SQ-NET-ADAP
AUD795.00
Availability: 1 week
 
Serial/ethernet converter kit
  
OM-SQ-GSM-KIT
AUD1,285.00
Availability: 1 week
 
GSM modem kit
  
OM-SQ-RF-ADAP
Consult Sales  
Availability: 
 
 
Wireless network adaptor
Click to expand/minimize a list of what others bought with theOM-SQ-UNIV-ADAP
OM-SQ-UNIV-ADAP
Consult Sales  
Availability: 
 
 
Universal power pack
  
OM-SQ-UNIV-ADAP-1
Consult Sales  
Availability: 
 
 
Universal power pack with 1 m (3.2') flying lead
  
OM-SQ-CS
AUD112.00
Availability: 1 week
 
Spare current shunts (package of 4)
  
OM-SQ-SER-CABLE
AUD78.00
Availability: 1 week
 
OM-SQ data logger to PC serial port cable
  
OM-SQ-USB-CABLE
Consult Sales  
Availability: 
 
 
Spare OM-SQ data logger to PC USB port cable
  
OM-SQ-TB3
Consult Sales  
Availability: 
 
 
Spare 3-way terminal block with cable restraint
  
OM-SQ-TB4
Consult Sales  
Availability: 
 
 
Spare 4-way terminal block with cable restraint
  
OM-SQ-TB6
Consult Sales  
Availability: 
 
 
Spare 6-way terminal block with cable restraint
  
OM-SQ-SOFT-PLUS
Consult Sales  
Availability: 
 
 
OM-SQ2040 plus software
  
OM-SQ-SOFT-PLUS-LIC
Consult Sales  
Availability: 
 
 
OM-SQ2040 plus software multi-user license
All amounts shown in AUD
Note: Comes with software, manual, USB cable, wall bracket, 6 “AA” batteries, 10 input terminal blocks, 4 current shunt resistors and complete operator’s manual. To order data logger with calibration certificate, add suffix “-CAL” to model number and add $445 to the price.
 
We noticed you are from the US. Visit your local site for regional offers and live support.