Description
This product has been discontinued. For a possible replacement please see CL309A. Questions? Feel free to call one of our application engineers to help find the solution that is best for you.
The OMEGA™ CL100 Series are compact, easy-to-use handheld calibrators that provide a precision output signal. Models includes thermocouple calibrators, temperature calibrators, or process calibrators. Units do not read signals. Models are available that specialize in simulating thermocouples, voltage and output signals.
General Specifications
Battery: 9V Alkaline (included)
Displays: 4 and 5 digits
Operating Temperature:0 to 50°C (32 to 122°F)
Storage Temperature:-20 to 60°C (-4 to 140°F)
Operating/Storage Humidity:< 85% relative
Dimensions:88 x 168 x 26 mm (3.5 x 6.6 x 1")
Weight: 330 g (11.6 oz.)
CL123
Features
4-20 mA (1K. load, 24 V loop supply)
0-100.00 mV, 0-1.0000 V, 0-12.000 V
K,J,E,T Thermocouples (°C & °F)
Frequency 1-62500 Hz
0-20 mA, 0-24 mA Selectable
0-100% range setting in mA, mV, V, mode
Beeper Warning when Output is Open (mA)
Basic Accuracy: 0.025%
0-24 mA ±0.025% ±0.003 mA
0-100 mV ±0.05% ±0.03 mV
0-1 V ±0.05% ±0.0003 V
0-10 V ±0.05% ±0.003 V
Thermocouples:
K: -200 to 1370, ±0.9°C
J: -100 to 760, ±0.8°C
E: -100 to 700, ±0.7°C
T: -200 to 400, ±0.8°C
Frequency: 1 to 125 Hz, ±0.04 Hz, 126 to 62,500 Hz, ±0.01% ±0.04 Hz (604 Available Frequencies)
Thermocouple Connection:SMP (miniature) type on front
Process Connection:45 cm (18") red and black leads attached to side of unit
CL125
Features
11 Types of Thermocouples
°C, °F, K Temperature Scales
Internal/External Temperature Reference
Auto-Ramp and .T Function
Easy Keypad Programming
Basic Accuracy: 0.3°C/0.6°F
Resolution: 0.1°C/0.2°F (K,J,E,T,N,U,L)
0.2°C/0.4°F (R,S,B,C)
Range:
K: -200 to 1370°C R: 0 to 1767°C
J: -200 to 1200°C S: 0 to 1767°C
E: -200 to 1000°C B: 600 to 1800°C
T: -200 to 400°C N: -200 to 1300°C
C: 0 to 2300°C U: -200 to 600°C
L: -200 to 900°C
Thermocouple Connection:SMP (miniature) type on front
CL100MA
Features
4-20 mA with 1 µA resolution
Auto-Ramp and Easy Step Functions
1-100% Input
0-20 mA, 0-24 mA Selectable
Easy Keypad Programming
Range | Resolution | Accuracy |
0-4 mA | 0.001 mA | 0.025% + 10 µA |
4-20 mA | 0.001 mA | 0.025% + 5 µA |
20-24 mA | 0.001 mA | 0.025% + 5 µA |
Process Connection: 45 cm (18") red and black leads attached to side of unit
† All amounts shown in AUD
Note: Each unit supplied with rugged carrying case, complete operator’s manual, 9 V battery, external battery pack (without batteries) holds four AA batteries (models CL123 & CL100MA), type K thermocouple (models CL123, CL125), test leads and alligator clip (models CL123 & CL100MA). Units are for simulation (not reading) of temperature or process signals.
Product Manuals:
Download
CL100MA - 4-20 mA Loop Calibrator
Download
CL125 - Handheld Multifunction Calibrator
Download
CL123 - Handheld Multifunction Calibrator