Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners

DRLP Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners | DRLP Series

AUD555.00 DRLP-MV1

CE
  • ±0.03% Accuracy (Typical)
  • ±0.01% Linearity
  • 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection
  • ANSI/IEEE C37.90.1 Transient Protection
  • Wide Loop Supply Voltage, 10.8V to 60V
  • 5-Pole Low-Pass Filtering
  • Up to 160 dB CMR
  • 85dB NMR at 60Hz, 80dB at 50Hz
  • Protected Against Reverse Connection of Loop Voltage
  • -40 to 80°C (-40 to 176°F) Operating Temperature
  • Mounts on DIN Rail EN 50022, 35 x 7.5 or 35 x 15
  • CE Compliant
  • Manufactured per RoHS Directive 2002/95/EC
Temperature Transmitters - View related products

Description

The new DRLP Series of loop powered 2-wire transmitters consists of seven family groups with a total of 48 transmitter models that interface to a wide variety of voltage, current, temperature and position measuring devices. The DRLP Series provides superior specifications such as ±0.03% accuracy, five poles of filtering, 1500 Vrms continuous isolation, low output noise, and much more. The DRLP Series 2-wire transmitter conditions and sends analog signals from sensors located in the “field” to monitoring and control equipment, usually computers, located thousands of feet away in central control areas. The DRLP Series accepts a wide range of inputs, including millivolt, volt, milliamp, thermocouple, RTD, potentiometer, and slide wire. It operates on power from a 2-wire signal loop and modulates the supply current to represent the input signal within a 4 to 20-milliamp range. Two-wire transmission loops are very economical methods for connecting sensors to distant control rooms. Since the DRLP Series operates from the signal loop current, no additional, expensive power and wiring are required. Only low cost, twisted pair wiring is needed.

DRLP Loop Drive Capability
The DRLP Series transmitter’s wide range of loop supply voltage (10.8V to 60V) makes it a versatile device which can be used in most any current loop. The maximum loop resistance is determined by subtracting the transmitter’s minimum loop supply voltage from the total loop supply voltage and dividing the result by the maximum loop current (see graph). The low loop supply voltage of 10.8V allows the DRLP to be used in applications with low output power supplies and the high Loop Supply Voltage of 60V allows use in applications with long distance current loops.

COMMON SPECIFICATIONS
Input Protection
  Continuous: 240 Vrms maximum
  Transient: ANSI/IEEE C37.90.1
CMV, Input to Output
  Continuous: 1500 Vrms maximum
  Transient: ANSI/IEEE C37.90.1
Noise
  Output: 100 kHz:3µArms
Output Range: 4 to 20 mA
Output Protection
  Reverse Polarity: Continuous
  Over-Voltage: 240 Vrms continuous
  Transient: ANSI/IEEE C37.90.1
Loop Supply Voltage: 10.8V to 60V
Loop Supply Sensitivity: ±0.0005%/V
Turn-On Delay: 400 ms
Environmental
  Operating Temperature Range: -40 to 80°C (-40 to 176°F)
  Storage Temperature Range: -40 to 80°C (-40 to 176°F)
Relative Humidity: 0 to 95% non-condensing
Emissions EN61000-6-4: ISM, Group 1
  Radiated, Conducted: Class A
Immunity EN61000-6-2: ISM, Group 1
  RF: Performance A ±0.5% span error
  ESD, EFT: Performance B
Mechanical Dimensions: 75 H x 22.5 W x 105 mm D (2.95 x 0.89 x 4.13")
Mounting: DIN EN 50022 35 x 7.5 mm or 35 x 15 mm rail

See attached PDF for detailed Transmitter Specifications
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
DRLP-MV/DRLP-V (Voltage Input)
  
DRLP-MV1
AUD555.00
Availability: 7 weeks
 
±10 mV Input Range
  
DRLP-MV2
AUD555.00
Availability: 7 weeks
 
±50 mV Input Range
  
DRLP-MV3
AUD555.00
Availability: 7 weeks
 
±100 mV Input Range
  
DRLP-MV4
AUD555.00
Availability: 7 weeks
 
0 to 10 mV Input Range
  
DRLP-MV5
AUD555.00
Availability: 7 weeks
 
0 to 50 mV Input Range
  
DRLP-MV6
AUD555.00
Availability: 7 weeks
 
0 to 100 mV Input Range
  
DRLP-V1
AUD555.00
Availability: 7 weeks
 
±1V Input Range
  
DRLP-V2
AUD555.00
Availability: 7 weeks
 
±5V Input Range
  
DRLP-V3
AUD555.00
Availability: 7 weeks
 
±10V Input Range
  
DRLP-V4
AUD555.00
Availability: 7 weeks
 
0 to 1V Input Range
  
DRLP-V5
AUD555.00
Availability: 7 weeks
 
0 to 5V Input Range
  
DRLP-V6
AUD555.00
Availability: 7 weeks
 
0 to 10V Input Range
  
DRLP-V7
AUD555.00
Availability: 7 weeks
 
±20V Input Range
  
DRLP-V8
AUD555.00
Availability: 7 weeks
 
0 to 20V Input Range
DRLP-C (Current Input)
  
DRLP-C1
AUD625.00
Availability: 7 weeks
 
4 to 20 mA Input Range
  
DRLP-C2
AUD625.00
Availability: 7 weeks
 
0 to 20 mA Input Range
DRLP-RTD (Pt RTD Input)
  
DRLP-RTD1
AUD630.00
Availability: 7 weeks
 
100 Ω Pt -100 to 100°C (-148 to 212°F) Input Range
  
DRLP-RTD2
AUD630.00
Availability: 7 weeks
 
100 Ω Pt 0 to 100°C (32 to 212°F) Input Range
  
DRLP-RTD3
AUD630.00
Availability: 7 weeks
 
100 Ω Pt 0 to 200°C (32 to 392°F) Input Range
  
DRLP-RTD4
AUD630.00
Availability: 7 weeks
 
100 Ω Pt 0 to 600°C (32 to 1112°F) Input Range
  
DRLP-RTD5
AUD630.00
Availability: 7 weeks
 
100 Ω Pt 0 to 400°C (32 to 752°F) Input Range
DRLP-RTD6 (Ni RTD Input)
  
DRLP-RTD6
AUD630.00
Availability: 7 weeks
 
120 Ω Ni 0 to 300°C (32 to 572°F) Input Range
DRLP-P (Potentiometer Input)
  
DRLP-P1
AUD585.00
Availability: 7 weeks
 
0 to 100Ω Input Range
  
DRLP-P2
AUD585.00
Availability: 7 weeks
 
0 to 500Ω Input Range
  
DRLP-P3
AUD585.00
Availability: 7 weeks
 
0 to 1 kΩ Input Range
  
DRLP-P4
AUD585.00
Availability: 7 weeks
 
0 to 10 kΩ Input Range
DRLP-ITC (Non-Linearized Thermocouple Input)
  
DRLP-ITC-J
AUD690.00
Availability: 7 weeks
 
J T/C, -100 to 760°C (-148 to 1400°F) Input Range
  
DRLP-ITC-K
AUD690.00
Availability: 7 weeks
 
K T/C, -100 to 1350°C (-148 to 2462°F) Input Range
  
DRLP-ITC-T
AUD690.00
Availability: 7 weeks
 
T T/C, -100 to 400°C (-148 to 752°F) Input Range
  
DRLP-ITC-E
AUD690.00
Availability: 7 weeks
 
E T/C, 0 to 900°C (32 to 1652°F) Input Range
  
DRLP-ITC-R
AUD690.00
Availability: 7 weeks
 
R T/C, 0 to 1750°C (32 to 3182°F) Input Range
  
DRLP-ITC-S
AUD690.00
Availability: 7 weeks
 
S T/C, 0 to 1750°C (32 to 3182°F) Input Range
  
DRLP-ITC-B
AUD690.00
Availability: 7 weeks
 
B T/C, 0 to 1800°C (32 to 3272°F) Input Range
  
DRLP-ITC-N
AUD690.00
Availability: 7 weeks
 
N T/C, -100 to 1300°C (-148 to 2372°F) Input Range
DRLP-LTC (Linearized Thermocouple Input)
  
DRLP-LTC-J1
AUD715.00
Availability: 7 weeks
 
J T/C, 0 to 760°C (32 to 1400°F) Input Range
  
DRLP-LTC-J2
AUD715.00
Availability: 1 week
 
J T/C, -100 to 300°C (-148 to 572°F) Input Range
  
DRLP-LTC-J3
AUD715.00
Availability: 7 weeks
 
J T/C, 0 to 500°C (32 to 932°F) Input Range
  
DRLP-LTC-K1
AUD650.00
Availability: 7 weeks
 
K T/C, 0 to 1000°C (32 to 1832°F) Input Range
  
DRLP-LTC-K2
AUD650.00
Availability: 7 weeks
 
K T/C, 0 to 500°C (32 to 932°F) Input Range
  
DRLP-LTC-K3
AUD650.00
Availability: 7 weeks
 
K T/C, -100 to 1350°C (-148 to 2462°F) Input Range
  
DRLP-LTC-K4
AUD650.00
Availability: 7 weeks
 
K T/C, 0 to 1200°C (32 to 2192°F) Input Range
  
DRLP-LTC-T1
AUD650.00
Availability: 7 weeks
 
T T/C, -100 to 400°C (-148 to 752°F) Input Range
  
DRLP-LTC-T2
AUD650.00
Availability: 7 weeks
 
T T/C, 0 to 200°C (32 to 392°F) Input Range
  
DRLP-LTC-E
AUD715.00
Availability: 7 weeks
 
E T/C, 0 to 1000°C (32 to 1832°F) Input Range
  
DRLP-LTC-R
AUD650.00
Availability: 7 weeks
 
R T/C, 500 to 1750°C (932 to 3182°F) Input Range
  
DRLP-LTC-S
AUD650.00
Availability: 7 weeks
 
S T/C, 500 to 1750°C (932 to 3182°F) Input Range
  
DRLP-LTC-B
AUD715.00
Availability: 7 weeks
 
B T/C, 500 to 1800°C (932 to 3272°F) Input Range
  
DRLP-LTC-N
AUD650.00
Availability: 7 weeks
 
N T/C, -100 to 1300°C (-148 to 2372°F) Input Range
ACCESSORIES
  
RAIL-35-1
AUD29.58
Availability: 1 week
 
35 mm DIN rail, 1 m (3.3') length
Click to expand/minimize a list of what others bought with theRAIL-35-2
RAIL-35-2
AUD56.00
Availability: 1 week
 
35 mm DIN rail, 2 m (6.6') length
All amounts shown in AUD
Ordering Example: (1) DRLP-MV1 ±10 mV Input Range, AUD555.00  plus (1) RAIL-35-1 35 mm DIN rail, 1 m (3.3') length, AUD29.58, AUD555.00 + 29.58 = AUD584.58

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Thermocouple select from:
Nothing(leave field blank) for None Thermocouple Models
-ITC for Non-Linearized Thermocouple Input
-LTC for Linearized Thermocouple Input

(2) Input Range select from:
MV1 for ± 10 mV
MV2 for ± 50 mV
MV3 for ± 100 mV
MV4 for 0 to 10 mV
MV5 for 0 to 50 mV
MV6 for 0 to 100 mV
V1 for ± 1V
V2 for ± 5V
V3 for ± 10V
V4 for 0 to 1V
V5 for 0 to 5V
V6 for 0 to 10V
V7 for ± 20V
V8 for 0 to 20V
C1 for 4 to 20 mA
C2 for 0 to 20 mA
RTD1 for -100 to 100°C (-148 to 212°F)
RTD2 for 0 to 100°C (32 to 212°F)
RTD3 for 0 to 200°C (32 to 392°F)
RTD4 for 0 to 600°C (32 to 1112°F)
RTD5 for 0 to 400°C (32 to 752°F)
RTD6 for 0 to 300°C (32 to 572°F) 120 Ohm Ni.
P1 for 0 to 100 Ohm
P2 for 0 to 500 Ohm
P3 for 0 to 1 k Ohm
P4 for 0 to 10 k Ohm
J for -100 to 760°C (-148 to 1400°F) Non-Linearized Type J Thermocouple
K for -100 to 1350°C (-148 to 2462°F) Non-Linearized Type K Thermocouple
T for -100 to 400°C (-148 to 752°F) Non-Linearized Type T Thermocouple
E for 0 to 900°C (32 to 1652°F) Non-Linearized Type E Thermocouple
R for 0 to 1750°C (32 to 3182°F) Non-Linearized Type R Thermocouple
S for 0 to 1750°C (32 to 3182°F) Non-Linearized Type S Thermocouple
B for 0 to 1800°C (32 to 3272°F) Non-Linearized Type B Thermocouple
N for -100 to 1300°C (-148 to 2372°F) Non-Linearized Type N Thermocouple
J1 for 0 to 760°C (32 to 1400°F) Linearized Type J Thermocouple
J2 for -100 to 300°C (-148 to 572°F) Linearized Type J Thermocouple
J3 for 0 to 500°C (32 to 932°F) Linearized Type J Thermocouple
K1 for 0 to 1000°C (32 to 1832°F) Linearized Type K Thermocouple
K2 for 0 to 500°C (32 to 932°F) Linearized Type K Thermocouple
K3 for -100 to 1350°C (-148 to 2462°F) Linearized Type K Thermocouple
K4 for 0 to 1200°C (32 to 2192°F) Linearized Type K Thermocouple
T1 for -100 to 400°C (-148 to 752°F) Linearized Type T Thermocouple
T2 for 0 to 200°C (32 to 392°F) Linearized Type T Thermocouple
E for 0 to 1000°C (32 to 1832°F) Linearized Type E Thermocouple
R for 500 to 1750°C (932 to 3182°F) Linearized Type R Thermocouple
S for 500 to 1750°C (932 to 3182°F) Linearized Type S Thermocouple
B for 500 to 1750°C (932 to 3182°F) Linearized Type B Thermocouple
N for -100 to 1300°C (-148 to 2372°F) Linearized Type N Thermocouple
Note: All combinations may not be valid, check spec sheet for valid part numbers.

Product Manuals:

Download French Version - Régulateurs de process et de température
Download Isolated DIN Rail Mount 2-WireTrasmitters
We noticed you are from the US. Visit your local site for regional offers and live support.