Filter Fan for Larger Enclosures

FF018 Large Series

Filter Fan for Larger Enclosures | FF018 Large Series

Filter Fan for Larger Enclosures

CE
  • Very Low Noise
  • Minimal Depth in Enclosure
  • Functional Design
  • Time-Saving Installation
  • Require an Exhaust Filter to operate properly (EF118)
NEMA Electrical Enclosures - View related products

Description

In addition to the easy mounting axial fan, the self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet. The functional design of the intake and exhaust fan hoods very effectively prevents direct infiltration of falling water and dust. The design also provides air channeling which makes the filter fan particularly quiet in operation.

SPECIFICATIONS
Air Flow Free Blowing:
    FF01803011: 300 m3/h (176 cfm)
    FF01805001: 550 m3/h (323 cfm)
Air Flow with Exhaust Filter:
    FF0180301: 230 m3/h (135 cfm)
    FF01805001: 300 m3/h (176 cfm)
Current Consumption 120V:
    FF0180301: 700 mA
    FF01805001: 780 mA
Power Consumption 120V:
    FF0180301: 60 W
    FF01805001: 85 W Average Noise Level at 1 m (3')
(DIN EN ISO 9614-2):
    FF0180301: 53 db (A)
    FF01805001: 65 db (A)
Mounting Depth:
    FF0180301: 65 mm (2.6")
    FF01805001: 107 mm (4.2")
Enclosure Cut-Out: 176 x 176 mm ±0.4 (6.9 x 6.9")
Weight:
    FF0180301: 3.3 kg (7.3 lb)
    FF01805001: 2.7 kg (5.9 lb)
Axial Fan: Ball bearing, aluminum frame, plastic impeller UL94V-0, operational life min 50,000 hrs at 25°C (77°F) (RH 65%); operating temperature -45 to 70°C (-49 to 158°F) 2 lead wires 102 mm (4") long with pressure clamps, type AWG 14 max
Filter Fan and Exhaust Filter Housing: Plastic, UL94V-0, color light gray, UV resistant (rated F1), storage temperature -45 to 70°C (-49 to 158°F)
Mounting Frame: With double sided industrial adhesive band for affixing to the outside of enclosure; certain operating circumstances may make the additional use of screws necessary
Filter Material: Synthetic fiber with progressive construction, temperature resistant to 100°C (212°F), selfextinguishing class F1; moisture resistant to 100% RH. Can be cleaned by washing or vacuuming for reuse.
Protection: Standard filter mats G4, IP54; using fine filter mats F5 increases the protection to IP55 but reduces the air volume

EXHAUST FILTER SPECIFICATIONS
Filter Mat: Medium Grade 350 g/m2, filtering degree 94% for particle Ø<10 m, G4 (EN 779)
Mounting Depth: 22 mm (0.9")
Enclosure Cut-Out: 250 x 250 mm ±0.4 (9.8 x 9.8")
Weight: 0.95 kg (2.1 lb)
Dimensions:
    FF0180301: 300 m3/h (176 cfm)
    FF01805001: 550 m3/h (323 cfm)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
FF01803000
AUD715.00
Availability: 1 week
 
Standard filter fan, 300 m3/h (176 cfm). It needs exhaust filter.
FF01805001
Consult Sales  
Availability: 
 
 
Standard filter fan, 550 m3/h (323 cfm). It needs an exhaust filter.
EF11803000
AUD315.00
Availability: 6 weeks
 
Exhaust filter 350 g/m3, filtering degree 94% for particle Ø<10 m, G4 (EN 779). This item is required for either part number above.
All amounts shown in AUD
Note: Comes with complete operator’s manual.