Portable Temperature/Humidity Data Loggers With Graphic Display

OM-EL-GFX Series

Portable Temperature/Humidity Data Loggers With Graphic Display | OM-EL-GFX Series

AUD352.07 OM-EL-GFX-1

CE
  • Graphic LCD Shows Real-Time Readings, Graph and Current Status
  • Memory: 252,928 Readings
  • On Screen Menu and Graphing to Start, Stop, Review and Restart the Logger in the Field
  • Micro USB Interface for PC Based Set-Up and Data Download
  • Immediate, Delayed, Pushbutton or Temperature Triggered Start Mode
  • User Programmable Alarm Thresholds
  • User Enabled Audible Alarm
  • Highly Visible Confidence/Alarm LEDs
  • Rugged and Robust IP67 Construction
Data Loggers - View related products

Description

The OM-EL-GFX Series portable temperature/ humidity data loggers measure and store up to 252,928 readings. Using the included Windows® control software users can quickly set up the data logger and view downloaded data by connecting the device to the computer’s USB port.

The data logger features a high contrast graphic LCD display and three input buttons. This allows users to start, stop and restart the data logger using on-screen menus. The menu also provides real-time analysis of data either as a data summary (showing highest and lowest readings and alarm conditions) or as a graph that updates as new data is added. The maximum and minimum readings and also the time and date these are valid from can be displayed on the LCD display by using the info button. If desired, the user can then reset the maximum/minimum readings shown. Each time the maximum/minimum readings are reset while logging, an “event marker” is created in the data. When the data has been downloaded to the computer these events can be viewed on the graph (event markers), and they also appear in the data file associated with the corresponding log when the reset took place. This can be useful as an audit/validation tool for certain applications where procedures mandate that a regular physical check of the logger/statistics have taken place. Multiple data logging sessions can be stored on the device ready for upload to the computer at a later time.

The data logger’s robust design provides IP67 waterproof protection (OM-EL-GFX-1, OM-EL-GFX-2 and OM-EL-GFX-2-PLUS only).

Specifications
OM-EL-GFX-1
Measurement Range: -30 to 80°C (-22 to 176°F)
Internal Resolution: 0.1°C (0.1°F)
Accuracy (Overall Error @ 25°C): ±0.1°C (±0.2°F) typical; ±0.75°C (±1.5°F) maximum
Logging Interval: 1 reading every 10 seconds to 1 every hour
Battery Life: 6 months typical at 25°C (77°F) and 10 minute logging rate
Weight: 99 g (3.5 oz)
Dimensions: 88 H x 48.5 W x 30.5 mm D (3.46 x 1.91 x 1.20")

OM-EL-GFX-2, OM-EL-GFX-2-PLUS
Temperature
    Measurement Range: -30 to 80°C (-22 to 176°F)
    Repeatability: ±0.1°C (±0.2°F) typical
    Internal Resolution: 0.1°C (0.1°F)
    Accuracy (Overall Error): OM-EL-GFX-2; ±0.5°C (±1.0°F) typical; ±2.0°C (±4.0°F) maximum:
OM-EL-GFX-2-PLUS; ±0.2°C (±0.4°F) typical; ±0.8°C (±1.6°F) maximum
Humidity
    Measurement Range: 0 to 100% RH
    Repeatability: ±0.5% RH
    Long Term Stability: ±0.5% RH/year
    Internal Resolution: 0.1% RH
    Accuracy (20 to 80% RH): OM-EL-GFX-2; ±3.0% RH typical; ±5.0% RH maximum:
OM-EL-GFX-2-PLUS; ±1.8% RH typical; ±4.0% RH maximum
Dew Point
    Accuracy (Overall error in the calculated dew point, for RH measurement between 40 to 100% RH @ 25°C): ±1.1°C (±2.0°F)
Logging Interval: 1 reading every 10 seconds to 1 every hour
Battery Life: 4 months typical at 25°C (77°F) and 10 minute logging rate
Dimensions: 88 H x 48.5 W x 30.5 mm D (3.46 x 1.91 x 1.20")
Weight: 99 g (3.5 oz)

OM-EL-GFX-DTC (2 channels)
OM-EL-GFX-TC (1 channel)
Temperature Measurement Range:
    Type K: -200 to 1350°C (-328 to 2462°F)
    Type J: -200 to 1190°C (-328 to 2174°F)
    Type T: -200 to 390°C (-328 to 734°F)
Internal Resolution: 0.1°C (0.1°F)
Accuracy (Overall Error @ 25°C): ±0.5°C (±0.9°F) typical
Operating Temperature Range: -10 to 40°C (-14 to 104°F)
Logging Interval: 1 reading every 2 seconds to 1 every hour
Battery Life:
     OM-EL-GFX-DTC: 4 months typical at 25°C (77°F) and 10 minute logging rate
     OM-EL-GFX-TC: 1 year typical at 25°C (77°F) and 1 minute logging rate, LCD off
Weight: 105 g (3.7 oz)
Dimensions: 102 H x 48.5 W x 30.5 mm D (4.06 x 1.91 x 1.20")

OM-EL-GFX-DTP
Temperature Measurement Range (with Included Thermistor Probe): -40 to 125°C (-40 to 257°F)
Internal Resolution: 0.1°C (0.2°F)
Accuracy (Data Logger Error @ 25°C): ±0.1°C (±0.2°F) typical (does not include thermistor probe error)
Accuracy (Thermistor Probe): See chart on PDF
Operating Temperature Range: -10 to 40°C (-14 to 104°F)
Logging Interval: 1 reading every 2 seconds to 1 every hour
Battery Life: 4 months typical at 25°C (77°F) and 10 minute logging rate
Dimensions:
    Data Logger: 101 H x 48.5 W x 30.5 mm D (3.98 x 1.91 x 1.20")
    Thermistor Probe:
      Cable: 1 m (3')
      Probe Tip: Stainless steel, 25 L x 5 mm dia (1 x 0.18")
Weight: 105 g (3.7 oz)

COMMON SPECIFICATIONS
Memory: 252,928 readings
Software: Windows XP/VISTA/7 and 8 (32 and 64-bit)
Power: 2 ½ “AA” 3.6V lithium batteries (included)
Enclosure: IP67 with USB cover attached (excludes OM-EL-GFX-DTC, OM-EL-GFX-TC and OM-EL-GFX-DTP)
Display: High contrast graphic backlit LCD
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
OM-EL-GFX-1
AUD352.07
Availability: 1 week
 
Temperature data logger with graphic LCD display
OM-EL-GFX-2
AUD366.36
Availability: 1 week
 
Temperature and relative humidity data logger with graphic display
OM-EL-GFX-2-PLUS
AUD517.75
Availability: 1 week
 
High accuracy temperature and relative humidity data logger with graphic display
OM-EL-GFX-TC
AUD358.00
Availability: 1 week
 
Single channel K, J, and T Type thermocouple data logger with graphic display
OM-EL-GFX-DTC
AUD594.05
Availability: 1 week
 
Dual Channel K, J, and T Type thermocouple data logger with graphic display
OM-EL-GFX-DTP
AUD450.00
Availability: 8 weeks
 
Dual channel thermistor data logger with graphic display
Accessories
OM-EL-PROBE-TP-2-1M
AUD98.00
Availability: 8 weeks
 
Spare standard thermistor probe for OM-EL-GFX-DTP (2 included with data logger),1 m (3') cable
OM-EL-PROBE-TP-A-3M
AUD77.00
Availability: 1 week
 
Optional higher accuracy thermistor probe for OM-EL-GFX-DTP, 3 m (10') cable
OM-EL-PROBE-TP-A-GLY-3M
AUD168.00
Availability: 8 weeks
 
Optional higher accuracy thermistor probe (in sealed glycol filled chamber for temperature stabilization) for OM-EL-GFX-DTP, 3 m (10') cable
OM-EL-PROBE-EXT-CAB-1.5M
AUD32.00
Availability: 8 weeks
 
Thermistor probe extension cable, 1.5 m (5') for OM-EL-GFX-DTP
OM-EL-PROBE-EXT-CAB-5M
AUD45.00
Availability: 8 weeks
 
Thermistor probe extension cable, 5 m (16.5') for OM-EL-GFX-DTP
OM-EL-PROBE-EXT-CAB-10M
AUD51.00
Availability: 8 weeks
 
Thermistor probe extension cable, 10 m (33') for OM-EL-GFX-DTP
All amounts shown in AUD
Note:
Calibration Certification is available with extra charge and please contact Sales Department for more details.

Comes complete with Windows software and operator’s manual on CD-ROM, 2½ AA 3.6V lithium batteries, USB cover, mounting clip and 1 m (3.2') USB cable. OM-EL-GFX-DTC also includes 2 Type K insulated beaded wire thermocouples.

This product page contains items that either have a Lithium Battery installed in the equipment or have a Lithium Battery packed with the equipment. These items as being regulated for air transportation. The following applies:
• No FX1D, FX2D or FX3D can be used as a ship method.
• Only UPS1, UPS2 or UPS3 is authorized.
• For International shipments UPS and DHL can be used. For DHL internationally – Omega only has permission to ship Lithium Batteries no other Hazardous Material.
Ordering Example: (1) OM-EL-GFX-1 Temperature data logger with graphic LCD display, AUD352.07

Product Manuals:

Download Datalogger with Graphic Screen
Download Temperature Data logger with Graphics
Download Temperature and Humidity Datalogger with Graphic Screen
Download Dual Channel Temp Probe Datalogger
Download Dual Channel Thermocouple Datalogger with Graphic Screen
Download Thermocouple Datalogger with Graphic Display
Download Quick Start Manual
We noticed you are from the US. Visit your local site for regional offers and live support.