SPECIFICATIONS
Excitation: 10 Vdc (5 to 10 Vdc limits) Output: 0 to 100 mV @ 10 Vdc Sensitivity: 10 mV/V Input Impedance: 1500 Ω Output Impedance: 100 Ω Insulation Resistance: 100 MΩ @50 Vdc Accuracy: ±0.4% BFSL Hysteresis: ±0.2% Repeatability: ±0.05% Stability: ±1%/year Zero Balance: ±1% Durability: 100 million cycles Operating Temp: -48 to 91°C (-55 to 195°F) Compensated Temp: -29 to 82°C (-20 to 180°F) Thermal Zero Effect: ±0.07% FS/°C Thermal Span Effect: ±0.07% FS/°C Proof Pressure:
15 to 2000 psi = 200%
3000 to 5000 psi = 150%
7500 to 20,000 psi = 120% Burst Pressure:
15 to 2000 psi = 800%
3000 to 20,000 psi = 500% Gages: Thin film polysilicon Diaphragm: 17-4 PH stainless steel Case: 300 Series stainless steel Pressure Connection: 15 to 10,000 psi: ¼ NPT 15,000 and 20,000 psi:9⁄16-18 UNF Aminco fitting Electrical Connection: 0.9 m (36") braided-shield PVC cable or connector Weight: 71 g (2.5 oz.) without cable Response time: 5 ms Construction: Sealed units (except PX602 ≤ 500 psi is vented to room)
† All amounts shown in AUD Note: Comes with complete operator’s manual. 15,000 and 20,000 psi models supplied with female AMINCO fitting. Ordering Example: (1) PT06F8-4S Mating Connector (sold separately), AUD57.97 plus (1) PX612-100GV a 100 psi connector style transducer, AUD760.00, AUD57.97 + 760.00 = AUD817.97
Part Number Builder
Build Your Part Number Below
Option Descriptions:
(1)
Cable or Connector Style select from: 02 for 3 foot cable 12 for 4 pin connector (mating connector sold separately)
(2)
Range select from: 015GV for 0 to 15 psi 030GV for 0 to 30 psi 060GV for 0 to 60 psi 100GV for 0 to 100 psi 150GV for 0 to 150 psi 200GV for 0 to 200 psi 300GV for 0 to 300 psi 500GV for 0 to 500 psi 1KGV for 0 to 1000 psi 2KGV for 0 to 2000 psi 3KGV for 0 to 3000 psi 5KGV for 0 to 5000 psi 7.5KGV for 0 to 7500 psi 10KGV for 0 to 10000 psi 15KGV for 0 to 15000 psi 20KGV for 0 to 20000 psi
Note: All combinations may not be valid, check spec sheet for valid part numbers.