Compact Portable Data Logger - Discontinued

RDXL120 Series

Compact Portable Data Logger | RDXL120 Series

Compact Portable Data Logger

CE
  • Thermocouple, RTD (PT100) and Voltage Inputs
  • Set Temperature and Voltage Independently for Each Channel
  • All Channel Adopt Universal Insulated Input
  • Easy-to-Read Screen Display
  • Data Can Be Saved at Max Speed of 100 ms
  • Acquire Large Amounts of Data
  • Easy-to-Read Wide View TFT LCD (Even Outdoors)
  • Employs Compact Flash and SD Cards
  • USB Memory Enables Support For a Data Copy Function
  • Supports Remote Data Acquisition

Description

The RDXL120 Series has been discontinued. Once stock is depleted it will no longer be available. Please review the OM-DAQXL Series as replacements or contact our Data Acquisition Department.

The channels in the analog input part adopt insulated inputs, which means that temperature (thermocouple/resistance temperature detector) and voltage can be set differently for each channel. Eleven types of thermocouples, Pt100 and JPt100 temperature-measuring resistors, and a voltage up to 50V range are supported.
The analog inputs are wired from the left, while the power and communication lines are wired from the right. This design makes the RDXL120 a suitable option in a narrow space.
Wiring is easy, since the terminal block can be removed easily with a single action. The dedicated lithium ion battery enables up to 7 hours of operation (typical). Resistance to impact is improved by the use of a rubber boot, which is removable. after the trigger).

Application Software
Datum-LOGGER software allows you to connect up to ten units to analyze and process data after you perform real-time measurement and acquire data with a PC.
Features:
  • Real-time measurement at the maximum speed of 1 second
  • Zooming to analyze acquired data in the waveform view
  • A variety of data saving functions available (selective and partial saving)
Standard Supplied Software D-TOOL software allows you to show data in waveforms and perform CSV conversion.
Main Function:
  • Waveform display of measured binary data
  • Enlarged view of waveforms along X/Y-axes
  • Display of respective data taken at two points (measured value, measurement time) and the result of inter-channel calculation (B - A)
  • Copy function (clipboard copy)
  • Conversion to CSV for storage (skipping, saving of data between cursors)
  • File division
  • Settings and creation of setting files
  • Windows XP supported environment
SPECIFICATIONS
Real-Time Measurement Data Acquisition Functions:

Communication Interface: Ethernet, USB, RS232, RS485
Max Number of Units That Can Be Connected: 10 units
Data Acquisition Channels (Per Unit): Sixteen analog channels, pulse channel, two logic channels, thirty-two XL unit calculation channels, four calculation channels dedicated to Datum-LOGGER software, thirty-two communication channels
Measurement Acquisition Period: 1, 2, 5, 10, 20, and 30 seconds, 1, 2, 5, 10, 20, 30 minutes, 1 hour (if the communication interface is RS485, the acquisition periods that can be set vary depending on the number of connected units; if the communication interface is ethernet and the communication interface set for the station is LAN/RS232 or LAN/RS485, the settable measurement periods will be 10 seconds or longer irrespective of the setting made to the Datum-LOGGER software.)

Display Functions
Display: Waveform, digital, bar graph, meter display
Cursor Value Display: Display of each measurement values, difference, maximum value, minimum value and average value of cursors A and B
Arbitrary Cursor List Display: Display a list of arbitrary cursors and comments inserted in a waveform graph
Alarm List Display: Display a list of alarms for acquired data
Analysis View Display: Display all specified channels, value differences between cursors A and B in descending or ascending order, and the rate of change in descending or ascending order
Horizontal Scroll: By scrolling a waveform display horizontally, it is possible to display data acquired in the past even during real-time acquisition Resizing the Horizontal Axis: Display all the acquired data or data between cursors A and B
Jump Function: Re-display a waveform centering on a data selected in the cursor value display, arbitrary cursor list display, alarm list display or analysis view display
Dedicated Calculation Functions (Available for Real-Time Measurement): Formula of maximum 16-stack consisting of measurement data, functions and operators of the same RDXL120 (station) can be set for up to four channels
Data Load Functions: RDXL120 main unit measurement files, Datum-LOGGER measurement files on PC
File Processing Functions:
    Partial Storage: Save data between cursors A and B
    Divided Storage: Save by specifying date/time intervals or store by dividing into specified number of files
    File Division: RDXL120 measurement data files and Datum-LOGGER software measurement data files stored on PC can be divided at the specified number of data interval or specified date/time interval
    Combined Storage: Combine and save divided sub files of Datum-LOGGER software measurement data files.
    Skipped Storage: Skip data using specified time intervals
    Storage Format: Binary format (dedicated for Datum-LOGGER software)
Report Format Storage: Save maximum, minimum and average of hourly reports, daily reports, weekly reports and monthly reports in CSV format; measurement data can be added to CSV data to be stored
Main Unit Setting Functions: Send/receive setting details, load setting files and save setting files via communication
Clipboard Copy Functions: Copy a displayed waveform image to the clipboard
Printing Functions: Print a displayed waveform image

Analog Input Section
Input Method: Floating unbalanced input, insulated between channels (terminal "b" is shared by resistance temperature detector inputs)
Number of Inputs:
    XL121: 8 channels
    XL122: 16 channels
Input Type: T/C, RTD (for screw type only), DCV
Range and Measurement Range:
    Reference Operating Conditions: Temperature (23 ±2°C), humidity (55 ±10% RH), power supply voltage (100 to 240 Vac), power supply frequency (50/60 Hz ±1% or less), warm-up (30 minutes or longer), without vibration, etc. that do not affect the operation of the instrument
    Reference Junction Compensation: Internal reference junction compensation is used
Reference Junction Compensation Accuracy: ±1°C
Maximum Input Voltage:
    Voltage Range of 1 Vdc or Below and TC: ±10 Vdc
    Voltage Range of 5 Vdc or Above: ±60 Vdc
Input Resistance: Approx 1 MΩ
Maximum Common Mode Voltage: 30 Vac RMS (50/60 Hz) or ±60 Vdc
Common Mode Rejection Ratio:
    100 dB or Above (50/60 Hz): Digital filter OFF
    140 dB or Above (50/60 Hz): Digital filter ON
Measurement Interval: 5 seconds (8-channel terminal block)/10 seconds (16-channel terminal block)
Normal Mode Rejection Ratio 50 dB or Above (50/60 Hz): Digital filter ON
Measurement Interval: 5 seconds (8-channel terminal block)/10 seconds (16-channel terminal block) Thermocouple Burnout Detection: Detection is turned ON constantly during thermocouple measurement (burnout upscale only) (display: "+*****")

Digital Input Section
Number of Inputs:
    Pulse Input: 1 channel
    Logic Input: 2 channels
Input Specification:
    Lo: Below 0.9V or terminal short-circuited
    Hi: 2.1V or higher or terminal open
Maximum Input Voltage: 10 Vdc

Display Section
Display Unit: 3.5" TFT color LCD (320 x 240 pixels)
Display Color:     
Trend/Bar Graphs: Selectable from 16 colors (red, green, blue, bluish purple, brown, orange, yellowish green, light blue, reddish purple, gray, lime, blue green, dark blue, yellow, olive, purple)
    Background Color: Selectable from white and black (waveform display area)
Update Interval: Max approx 1 sec (measurement interval)

Storage Functions
Measurement Interval: 100 ms (only when the 8-channel terminal block is used), 200 and 500 ms, 1, 2, 5, 10, 20, and 30 sec, 1, 2, 5, 10, 20, and 30 min, 1 hr
* The sampling interval during pulse input is greater than or equal to 1 s
* If the communication is set to LAN/RS232 or LAN/RS485, the sampling interval is set greater than or equal to 10 s

Internal Memory: 16 MB
External Storage Medium: Compact flash memory card (Type II), SD card, USB memory (only the copy function is supported by USB memory; only those USB memories that have been verified by OMEGA are recommended)
Save Mode:
File Division: Select NO DIVISION or DIVISION (specify DIVISION to save the data by dividing the data at constant time intervals from the start of the logging operation) Memory Full Operation: Select STOP, REPEAT, or DELETE
Alarm Functions (Alarm Output):
    Alarm Type: Hi (high limit), lo (low limit), window-in (within specified upper/lower range), window-out (outside specified upper/lower range) (only hi and lo are available for logic inputs)
    Alarm Delay Time Number of Measurements: 0 to 36,000
    Display: Alarm status is displayed in the status display area and measured values are displayed in red when an alarm occurs (selectable from non-hold and hold-type)
    Hysteresis: ON/OFF switchable (0.5% of span fixed, common to all channels) 4 channels (not insulated)
    Buzzer: ON/OFF switchable when being output
    Recording: Up to 120 sets of latest information can be recorded
    Output Format: Open collector, 5V pull-up resistor (100 kÙ)
    Contact Capacity: 5 to 40V, 100 mA
Filter Functions (Analog Input): Selectable from among OFF, 50 and 60 Hz
Average Functions (Analog Input): Moving average calculation ON/OFF, selectable from 1, 2, 5, 10 and 20 times
Automatic Measurement Functions: The setting file (AUTORUN.SET) saved in the CF card, SD card or USB memory is loaded automatically, and recording starts according to the contents of the file
Communications Functions: 2 simultaneous communications are possible such as LAN and RS485, LAN and RS232, ethernet (10BASE-T/100BASE-TX), USB running Windows® 2000 or XP on personal computer with USB port, RS232, RS485, serial communication MODBUS® protocol, standard protocol—transmission medium: LAN, USB, RS232 and RS485

Power Supply Section
Operating Voltage Range: 90 to 132, 180 to 264 Vac
Rated Supply Frequency: 50/60 Hz
Battery: Dedicated lithium ion battery (2400 mAh, 7.4V, OPTIONAL.
Battery Operation: Can be charged on the main unit only; the instrument runs on the AC adaptor when both battery and AC adaptor are used
Charging Function: The battery can be charged while the instrument is in use; charging takes approximately 8 hours
Standard Accessories:
Terminal Block: 8 channels (95052) or 16 channels (95053, 95055)
AC Adaptor: 100 to 240 Vac
Rubber Boot: Impact-protection (93036)
Screwdriver: For push-lock screws on the terminal block
CD-ROM: Standard software, USB driver, instruction manual, communication function manual, quick manual

General Specifications
Location for Use: Indoor, at an altitude of 2000 m (6561.6') or less
Operating Temperature/Humidity Range: 0 to 50°C (32 to 122°F) [0 to 40°C (32 to 104°F) if battery is used], 5 to 85% RH (no condensation)
Storage Temperature/Humidity Range: -20 to 60°C (-4 to 140°F), 90% RH or less (no condensation)
Insulation Resistance:
    Between Each Input Terminal and Frame: 20 MΩ or higher (500 Vdc)
    Between Input Terminals (Except for Terminal b):20 MΩ or higher (100 Vdc)
    Between Each Input Terminal and Digital Input/Output: 20 MΩ or higher (100 Vdc)
Withstanding Voltage:
    Between Each Input Terminal and Frame: 350 Vp-p (50/60 Hz), 1 min
    Between Input Terminals (Except for Terminal b): 350 Vp-p (50/60 Hz), 1 min
    Between Each Input Terminal and Digital Input/Output: 350 Vp-p (50/60 Hz), 1 min
Dimensions: Approx 155 W x 155 H x 55 mm D (6 x 6 x 2.2") (without projecting parts and rubber boot)
Weight: Approx 800 g (1.8 lb) (without battery and rubber boot)
Complying Standard:
    Safety Standards: EN61010-1; measurement category I (circuit voltage used ±60 Vdc); pollution degree 2; rated transient over voltage 350 Vp-p
    Emission: EN61326 Class A, EN55011 Class A Group 1
    EN61000-3-2, EN61000-3-3: This product class A for use in an industrial environment and may cause radio interference if used for domestic use; therefore, appropriate measures must be taken when using it for domestic use
Immunity: EN61326 Annex a (immunity test requirement for equipment used in commercial environment; performance criterion under immunity test environments: B (self-returnable performance deterioration)
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
RDXL121-D
Consult Sales  
Availability: 
 
 
8-channel plug in terminals
Click to expand/minimize a list of what others bought with theRDXL122-D
RDXL122-D
Consult Sales  
Availability: 
 
 
16-channel plug in terminals
Accessories
Click to expand/minimize a list of what others bought with theRDXL900
RDXL900
AUD760.00
Availability: 1 week
 
Data Logging Software (Windows 7 and Vista)
Click to expand/minimize a list of what others bought with theRDXL-91011
RDXL-91011
Consult Sales  
Availability: 
 
 
3 m (10') RS232 cable
  
RDXL-94009
Consult Sales  
Availability: 
 
 
Replacement lithium ion battery. RESTRICTIONS ON SHIPMENT. Consult with Engineering Support.
  
RDXL-91029
Consult Sales  
Availability: 
 
 
3 m (10') digital I/O cable
Click to expand/minimize a list of what others bought with theRCC-1000
RCC-1000
AUD123.38
Availability: 1 week
 
Rugged carrying case
  
OM-3000-SC
Consult Sales  
Availability: 
 
 
Soft carrying case
  
RDXL-93039
Consult Sales  
Availability: 
 
 
Stand
  
RDXL-93936
Consult Sales  
Availability: 
 
 
Replacement rubber boot
  
RDXL-95052
Consult Sales  
Availability: 
 
 
Terminal block(8-channel plug in)
  
RDXL-95053
Consult Sales  
Availability: 
 
 
Terminal block(16-channel plug in)
All amounts shown in AUD
Note: Comes complete with operator's manual, rubber boot, AC adaptor and CD-ROM standard software for file management and communication.

Product Manuals:

Download RDXL120 - Portable Data Logger, Quick Setup Manual
Download RDXL120 - Portable Data Logger, User Guide
Download RDXL120 - Communication Function
We noticed you are from the US. Visit your local site for regional offers and live support.