Four Type J, K, T, E, R, S or N Thermocouple Inputs and Two 3-Wire Pt100 RTD Inputs (RTD Connectors are Included)
Display and Log All 6 Channels Simultaneously or Individually
Scheduled and Manual Logging Start/Stop
4 GB SD Card Stores Up to 1 Year of Data
Display Maximum, Minimum, Average and Standard Deviation
Display Temperature Difference Between Any 2 Channels
Battery or Mains Powered (With Adaptor)
Touch Screen with Backlight
2-Channel Temperature Chart
Alarm Indication for Each Channel
Description
The old version of RDXL6SD is discontinued and please check the new version RDXL6SD-USB for details.
The RDXL6SD is a six-channel
touchscreen data logger that
accepts four thermocouples and
two RTD inputs. Each channel
has individually configurable
HI/LO alarms. The intuitive
touchscreen interface allows
each channel to be configured
separately for input type, math,
alarm and display options. All
six channels can be displayed
and logged simultaneously or
individually. Data can be logged
as fast as once a second and is
stored on the included 4 GB SD
card in Excel® compatible format.
Specifications Inputs: 4x thermocouple inputs (any
of the following types), for use with
miniature thermocouple connectors,
and 2 x 3-wire Pt100 inputs, for
use with 3-pole stereo 3.5 mm (0.14")
connectors (see below) Input Temperature Range: Type J: -200 to 1200°C Type K: -200 to 1372°C Type T: -200 to 400°C Type R: 0 to 1768°C Type S: 0 to 1768°C Type N: 0 to 1300°C Type E: -200 to 1000°C RTD: -200 to 850°C Temperature Accuracy: For Thermocouples: ±0.1% or 0.8°C For RTD: ±1.0% or 1.0°C Temperature Resolution: 0.1° for
temperatures below 1000°C or °F,
1° for temperatures above 1000°C
or °F Display: 72 mm (2.83") resistive
touch TFT, 320 x 240 pixels, backlit Configurable Parameters:
Temperature units, alarms, signal
processing, date and time, data
logging, power options, graph
channels Temperature Units: °F or °C Alarm Configuration: 12 x alarms
(2 per channel) with adjustable level,
individually configurable as HI or LO Signal Processing: Average,
minimum, maximum, standard
deviation, 2-channel temperature
difference Display Response Time: 1 second Operating Temperature: 0 to 50°C
(32 to 122°F) Power Supply: Two “AA” batteries,
5 Vdc adaptor (included) Current Draw: 250 mA while logging
with full display brightness; 60 mA
while logging in power saving mode Weight: 180 g (6.3 oz) without
batteries Dimensions: 136 W x 71 H x 32 D mm
(5.35 x 2.8 x 1.25") Pt100 Connectors (RTD):
Use stereo (3-pole) 3.5 mm (0.14")
connectors, wired as follows: Data Logging
Specifications Data Logging Interval: 1 to 86,400
seconds (1 day) Maximum SD Card Capacity:
4 GB SD Card (included) Variables Logged: Measured
temperature, cold junction
temperature, alarm events File Format: .csv (can be imported
to Excel) Configurable Parameters:
Sample period, number of samples,
scheduled start date and time
† All amounts shown in AUD Note: Comes complete with 5 Vdc adaptor, two “AA” batteries, four beaded wire Type K thermocouples, two RTD connectors,
4 GB SD card, operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.