Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

High Reliability Solid State Relays

SSRL240 and SSRL660 Series

High Performance Solid State Relays SSR | Omega Engineering | SSRL240 and  SSRL660 Series

High Performance Solid State Relays SSR | Omega Engineering

AUD67.95 SSRL240DC25

  • Solid State Relays SSR Rarted to 100 Amps
  • Multi-Million Cycle Life
  • Compatible with Temperature Controllers
  • Solid-State, SCR Design
  • Zero Voltage Switching
  • Control ac Lines to 660 Vac
  • AC and DC Control Signal Models
  • LED Input Status Indicator
Temperature and Process Controllers and Power Switching Devices - View related products

Description

The Omega's SSRL series of solid state relays are used to control large resistance heaters in conjunction with temperature controllers. Solid state relays are SPST, normally open switching devices with no moving parts, capable of millions of cycles of operation. By applying a control signal, an SSR switches ON the ac load current, just as the moving contacts do on a mechanical contactor. Three-phase loads can be controlled using 2 or 3 SSR’s. Use 3 SSR’s for Y or star 3-phase loads using a neutral line. Two SSR’s will control “delta” loads with no neutral line. Three solid state relays are also used when there is no neutral load to provide redundancy and extra assurance of control.

"Switching" takes place at the zero voltage crossover point of the alternating current cycle. Because of this, no appreciable electrical noise is generated, making SSR’s ideal for environments where there are apparatuses susceptible to RFI.

Common Specifications
Operating Temperature: -20 to 80°C (-5 to 175°F)
Storage Temperature:-40 to 80°C (-40 to 175°F)
Isolation: 4000 Vrms, input to output; 2500 Vrms input/output to ground
Capacitance: 8 pF, input to output (max)
Line Frequency Range: 47 to 63 Hz
Turn-On Time: 20 ms, ac; 05 cycle, dc
Turn-Off Time: 30 ms, ac; 05 cycle, dc

These SSR’s are of the twin SCR type, inherently more reliable and capable of higher overloads before failure than triacs. Heat is developed in a solid state relay due to the nominal voltage drop across the switching device. To dissipate the heat, an SSR must be mounted on a finned heat sink or aluminum plate. An SSR should be located where the ambient temperature is relatively low, since the current switching rating is lowered as the temperature increases. Another SSR characteristic is a small leakage current across the output when the relay is open. Because of this, a voltage will always exist on the load side of the device.

In comparing SSR’s with mechanical contactors, the SSR has a cycle life many times that of a comparably priced contactor. However, SSR’s are more prone to failure due to overload and improper initial wiring. Solid state relays can fail, contact closed, on overload circuits. It is essential that a properly rated, fast blowing I2T fuse be installed to protect the load circuit.

Finned heat sinks are anodized fabrications that come complete with tapped mounting holes and screws. See thermal rating curves and ordering instructions for proper selection.

All SSRL series relays come with a thermally conductive pad mounted on the baseplate. This will significantly improve the thermal conductivity between the heat sink and SSR baseplate. It is also suggested that 10-inch-pounds of torque be used on the SSR mounting screws.





Output Specifications for Vac and Vdc Input Models
Specifications10 Amp25 Amp50 Amp75 Amp100 Amp
Max On State Current10 A25 A50 A75 A100 A
Max On State Current100 mA
Max 1-Cycle Surge150 A300 A750 A1000 A1200 A
Max 1 sec Surge30 A75 A150 A225 A300 A
12T (60 Hz), A2sec416937245850006000


SSR240 Series Electrical Specifications
 Input-Control SignalOutput
Model No.TypeControl
Signal
Voltage
Control
Signal
Turn-On
Control
Signal
Turn-Off
Max
Input
Current
Peak
Voltage*
(60 Sec. Max.)
SSRL240AC10
SSRL240AC25
SSRL240AC50
SSRL240AC75
SSRL240AC100
ac
Control
Signal
90 to 280 Vac90 Vac10 Vac10 mA800 V
SSRL240DC10
SSRL240DC25
SSRL240DC50
SSRL240DC75
SSRL240DC100
dc
Control
Signal
3 to 32 Vdc3 Vdc1 Vdc14 mA800 V
SSRL660AC50
SSRL660AC75
SSRL660AC100
ac
Control
Signal
90 to 280 Vac90 Vac10 Vac10 mA1200 V
SSRL660DC50
SSRL660DC75
SSRL660DC100
dc
Control
Signal
4 to 32 Vdc4 Vdc1 Vdc14 mA1200 V
*Transients above table value should be suppressed.

SSR240 Series Output-Vac Load Specifications
Model No.Nominal
ac Line
Voltage
Nominal
Load
Current
Max.
Contact
Voltage Drop
Max. Off-State Leakage
(25°C max. ambient)
120 Vac240 Vac440 Vac
SSRL240AC10
SSRL240AC25
SSRL240AC50
SSRL240AC75
SSRL240AC100
24 to 280 Vac10 A
25 A
50 A
75 A
100 A
1.6 V0.1 mA0.1 mAN/A
SSRL240DC10
SSRL240DC25
SSRL240DC50
SSRL240DC75
SSRL240DC100
24 to 280 Vac10 A
25 A
50 A
75 A
100 A
1.6 V0.1 mA0.1 mAN/A
SSRL660AC50
SSRL660AC75
SSRL660AC100
48 to 660 Vac50 A
75 A
100A
1.6 V0.25 mA0.25 mA0.25 mA
SSRL660DC50
SSRL660DC75
SSRL660DC100
48 to 660 Vac50 A
75 A
100 A
1.6 V0.25 mA0.25 mA0.25 mA
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
Click to expand/minimize a list of what others bought with theSSRL240AC10
SSRL240AC10
AUD65.56
Availability: 1 week
 
ac Control Signal(280Vac line) 10 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240AC25
SSRL240AC25
AUD81.84
Availability: 1 week
 
ac Control Signal(280Vac line) 25 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240AC50
SSRL240AC50
AUD100.72
Availability: 1 week
 
ac Control Signal (280Vac line) 50 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240AC75
SSRL240AC75
AUD175.00
Availability: 1 week
 
ac Control Signal (280Vac line)75 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240AC100
SSRL240AC100
AUD194.00
Availability: 1 week
 
ac Control Signal (280Vac line) 100 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240DC10
SSRL240DC10
AUD57.81
Availability: 1 week
 
dc Control Signal (280 Vac line) 10 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240DC25
SSRL240DC25
AUD67.95
Availability: 1 week
 
dc Control Signal (280 Vac line) 25 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240DC50
SSRL240DC50
AUD99.46
Availability: 1 week
 
dc Control Signal (280 Vac line) 50 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240DC75
SSRL240DC75
AUD166.18
Availability: 1 week
 
dc Control Signal (280 Vac line) 75 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL240DC100
SSRL240DC100
AUD185.00
Availability: 1 week
 
dc Control Signal (280 Vac line) 100 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL660AC50
SSRL660AC50
AUD129.68
Availability: 12 weeks
 
ac Control Signal (660 Vac line) 50 A Nominal rating
  
SSRL660AC75
Consult Sales  
Availability: 
 
 
ac Control Signal (660 Vac line)75 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL660AC100
SSRL660AC100
AUD206.00
Availability: 1 week
 
ac Control Signal (660 Vac line) 100 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL660DC50
SSRL660DC50
AUD115.63
Availability: 1 week
 
dc Control Signal (660 Vac line) 50 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL660DC75
SSRL660DC75
AUD175.00
Availability: 1 week
 
dc Control Signal (660 Vac line) 75 A Nominal rating
Click to expand/minimize a list of what others bought with theSSRL660DC100
SSRL660DC100
Consult Sales  
Availability: 
 
 
dc Control Signal (660 Vac line) 100 A Nominal rating
Heat Sinks
Click to expand/minimize a list of what others bought with theFHS-1
FHS-1
AUD54.22
Availability: 1 week
 
Finned Heat Sink 2°C/W
Click to expand/minimize a list of what others bought with theFHS-2
FHS-2
AUD62.95
Availability: 1 week
 
Finned Heat Sink 1.2°C/W
Click to expand/minimize a list of what others bought with theFHS-6
FHS-6
AUD67.93
Availability: 1 week
 
Finned Heat Sink .7°C/W
Fuses
Click to expand/minimize a list of what others bought with theKAX-10
KAX-10
AUD129.68
Availability: 1 week
 
10 A 14 x 51 mm (0.6 x 2')
Click to expand/minimize a list of what others bought with theKAX-25
KAX-25
AUD112.05
Availability: 1 week
 
25 A 14 x 51 mm (0.6 x 2')
Click to expand/minimize a list of what others bought with theKAX-30
KAX-30
AUD181.00
Availability: 1 week
 
30 A 14 x 51 mm (0.6 x 2')
Click to expand/minimize a list of what others bought with theKAX-50
KAX-50
AUD326.18
Availability: 1 week
 
50 A 21 x 81 mm (0.8 x 3.2')
  
KBH-50
AUD288.00
Availability: 1 week
 
50 A 18 x 81 mm (0.7 x 3.2')
  
KBH-70
AUD265.52
Availability: 19 weeks
 
70 A 19 x 92 mm (0.7 x 3.6')
Fuse Holders
Click to expand/minimize a list of what others bought with theFB-1
FB-1
Consult Sales  
Availability: 
 
 
Single fuse, for KAX-10, KAX-25, KAX-30
Click to expand/minimize a list of what others bought with theFB-2
FB-2
AUD180.00
Availability: 8 weeks
 
Two fuse, for KAX-10, KAX-25, KAX-30
Click to expand/minimize a list of what others bought with theFB-3
FB-3
AUD320.00
Availability: 8 weeks
 
Three fuse, for KAX-10, KAX-25, KAX-30
Click to expand/minimize a list of what others bought with theBS-101
BS-101
AUD640.00
Availability: 7 weeks
 
Single fuse, for KAX-50, KAX-70, KAX-100, KBH (all models)
Shunt Resistors for Controllers with AC SSR (Triac) Output
  
SSRR20-12
Consult Sales  
Availability: 
 
 
2000 ohms, 12 watts
  
SSRR20-50
AUD22.03
Availability: 1 week
 
2000 ohms, 50 watts
  
SSRR15-12
Consult Sales  
Availability: 
 
 
1500 ohms, 12 watts
  
SSRR15-50
AUD20.25
Availability: 1 week
 
1500 ohms, 50 watts
All amounts shown in AUD
Note: All SSRL Series come with thermally conducting pad. Reference SSR330 Series for additional heat sinks.
Ordering Example: (1) SSRL240DC25 Solid state relay, AUD67.95

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Nominal AC Line Voltage Range select from:
240 for 24 to 280 Vac
660 for 48 to 660 Vac

(2) Type select from:
AC for AC control signal
DC for DC control signal

(3) Nominal Load Current select from:
10 for 10 AMP
25 for 25 AMP
50 for 50 AMP
75 for 75 AMP
100 for 100 AMP
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.