Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Surface and Insertion Probes

88000 Series Probes

Surface and Insertion Probes | 88000 Series Probes

Surface and Insertion Probes

AUD234.00 88308K

  • Straight and Right Angle Version
  • E and K Thermocouple Types
  • Small Surface Area Probes
  • Spring Loaded Compact Tip Styles
  • Pointed Tip Design Ideal for Measuring Soft and Semi-frozen Materials and Molten Plastics and Rubbers
  • Meet the Standard Limits of Error
  • TAS Adapter Sold Separately!!
Thermocouples - View related products

Description

Model 88008(*)
Micro-sensor probe, designed for precise measurements of small surface areas, such as transistors and integrated circuits. Small contact surface area of 0.040 x 0.118" for fast response. 400°C (750°F) max. surface temperature.
Note: element not replaceable.

Model 88009(*)
Thin-body type probe designed to measure the surface of the bottom of narrow gaps or slits, like that of a plate heater. 260°C (500°F) max. service temperature.
Note: element not replaceable.

Model 88013(*)
Fast-response spring-loaded compact tip probe, for measurements to 815°C (1500°F). Surface pad made from 400 series stainless steel. 0.187" dia. surface area. Not designed for long-term exposure to high temperatures.
Note: element not replaceable.

Model 88014(*)
Right angle version of the 88013. Fast-response spring-loaded compact tip probe, for measurements to 815°C (1500°F). Surface pad made from 400 series stainless steel. 0.187" dia. surface area. Not designed for long-term exposure to high temperatures.
Note: element not replaceable.

Model 88104(*)
Right angle version of the 88008, with unique lateral spring design and small contact surface area. 400°C (750°F) max. surface temperature.
Note: element not replaceable.

Model 88301(*)
Suitable for measuring internal temperatures of semi-solid materials, such as rubbers, plastics, clay, as well as for liquid measurements. Tapered stainless steel sheath with 480°C (900°F) max service temperature.
Note: element not replaceable.

Model 88305(*)
Measure temperatures in moving air, with drilled sheath protect the thermocouple, while exposing it to air flow. 0.5 to 20 second response time (depending on air velocity). 480°C (900°F) max service temperature.
Note: element not replaceable.

Model 88306(*)
Pointed tip design, ideal for measuring soft and semi-frozen material, molten plastics and rubbers. 4" sheath, with 6 to 20 s response time. 500°C (930°F) max service temperature.
Note: element not replaceable.

Model 88307(*)
Longer version of the 88306, with 12" sheath.
Note: element not replaceable.

Model 88308(*)
Specially designed fine hypodermic needle probe, least likely to disturb the surrounding insertion area. 6 to 20 second response time, 205°C (400°F) max. service temperature.
Note: element not replaceable.

*Specify Calibration: K: CHROMEGA™-ALOMEGA™ E: CHROMEGA-Constantan

All 88000 series probes are supplied with retractable cable [expands to 1.5 m (5')] and male subminiature connector.
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
88008
Click to expand/minimize a list of what others bought with the88008K
88008K
AUD414.15
Availability: 6 weeks
 
K Type, Small contact surface area of 0.040 x 0.118 inch, 400°C (750°F) maximum surface temperature.
  
88008E
AUD371.08
Availability: 6 weeks
 
E Type, Small contact surface area of 0.040 x 0.118 inch, 400°C (750°F) maximum surface temperature.
88104
Click to expand/minimize a list of what others bought with the88104K
88104K
AUD392.11
Availability: 9 weeks
 
K Type, Right Angle Version of the 88008 (shown above)
  
88104E
AUD414.15
Availability: 6 weeks
 
E Type, Right Angle Version of the 88008 (shown above)
88013
Click to expand/minimize a list of what others bought with the88013K
88013K
AUD396.08
Availability: 1 week
 
K Type, Spring-loaded compact tip, 0.187" dia. surface area, measurements to 815°C (1500°F).
  
88013E
AUD348.00
Availability: 5 weeks
 
E Type, Spring-loaded compact tip, 0.187" dia. surface area, measurements to 815°C (1500°F).
88014
Click to expand/minimize a list of what others bought with the88014K
88014K
AUD392.11
Availability: 1 week
 
K Type, Right Angle Version of Model 88013 (Shown above)
  
88014E
AUD364.00
Availability: 5 weeks
 
E Type, Right Angle Version of Model 88013 (Shown above)
88305
Click to expand/minimize a list of what others bought with the88305K
88305K
AUD245.00
Availability: 7 weeks
 
K type, Unique Air Probe with drilled sheath to protect thermocouple while allowing air to pass through, 480°C (900°F) maximum temperature
  
88305E
AUD220.00
Availability: 7 weeks
 
E type, Unique Air Probe with drilled sheath to protect thermocouple while allowing air to pass through, 480°C (900°F) maximum temperature
88306
Click to expand/minimize a list of what others bought with the88306K
88306K
AUD283.51
Availability: 7 weeks
 
K type, Pointed tip, 4 inch sheath, 500 deg C (930 deg F)
  
88306E
AUD283.51
Availability: 7 weeks
 
E type, Pointed tip, 4 inch sheath, 500 deg C (930 deg F)
88307
  
88307K
AUD283.51
Availability: 7 weeks
 
K type, Pointed tip, 12 inch sheath, 500 deg C (930 deg F)
  
88307E
AUD250.00
Availability: 7 weeks
 
E type, Pointed tip, 12 inch sheath, 500 deg C (930 deg F)
88301
Click to expand/minimize a list of what others bought with the88301K
88301K
AUD269.00
Availability: 1 week
 
K type, Pointed tip, 3 inch sheath, 480 deg C (900 deg F)
  
88301E
AUD284.00
Availability: 7 weeks
 
E type, Pointed tip, 3 inch sheath, 480 deg C (900 deg F)
88308
Click to expand/minimize a list of what others bought with the88308K
88308K
AUD234.00
Availability: 1 week
 
K type, Hypodermic needle probe, 1 1/2 inch sheath, 205 deg C (400 deg F)
  
88308E
AUD230.00
Availability: 7 weeks
 
E type, Hypodermic needle probe, 1 1/2 inch sheath, 205 deg C (400 deg F)
88009
  
88009K
AUD415.00
Availability: 6 weeks
 
K type, Thin body style, 260 deg F (500 deg C)
  
88009E
AUD364.00
Availability: 6 weeks
 
E type, Thin body style, 260 deg F (500 deg C)
Sold Separately, TAS Adapters
  
TAS-K-3
AUD20.55
Availability: 4 weeks
 
TAS Adapter
  
TAS-E-3
AUD21.31
Availability: 1 week
 
TAS Adapter
All amounts shown in AUD
Note: All 88000 series probes are supplied with retractable cable (expands to 5') and male subminiature connector. All probes meet the standard limits of error.


Ordering Example: (1) 88308K K type, Hypodermic needle probe, 1 1/2 inch sheath, 205 deg C (400 deg F), AUD234.00
We noticed you are from the US. Visit your local site for regional offers and live support.