Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Conductivity or Resistivity Controller - Discontinued

CDCN441

Conductivity or Resistivity Controller | CDCN441

Conductivity or Resistivity Controller

CE
  • Analyzer/Transmitter/Controller
  • Self-Guided Menu
  • Auto-Range Scales
  • Automatic Calibration and Check
  • Recognizes Standard and Cell
  • Automatic Temperature Compensation
  • On-Off/PWM Control
  • Programmable Transmitter Output
  • RS485 Output
Conductivity Instrumentation - View related products

Description

Discontinued, replaced by either CDCN-961-Controller Or AM-2250-Controller

.
The CDCN441 conductance/resistance analyzercontroller is designed for online monitoring of process solutions and water applications. Applications include: waste water treatment, power plants, thermo electric plants, pharmaceutical, photographic industries and soft drinks industries. The menus are self guiding with simple three button programming. Available control outputs include ON-OFF or pulse width modulation. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the cell used and the buffer solution resulting in a simple and straight forward system calibration.

Equipment is built with solid state technology, electronic contacts and not electrical contacts, avoiding mechanical movement and off course no sparks.

SPECIFICATIONS
General
Construction/Materials:
   Case: Aluminum (SAE323)
   Faceplate: ABS
Anti-Corrosion Treatment: Finished with electrostatic epoxy paint
Case Rating: NEMA 4 (IP68)
Power Consumption: 3.5 VA
Operation: 90-240 Vac; 50/60Hz
LCD Readout: 2 lines x 16 characters
Reading Modes: Continuous, average or hold
Assembly in 51 mm (2") Tube or Flat Surface or Panel: 144 x 144 x 100 mm DIN (5.7 x 5.7 x 4")
Weight: 1.3 kg (2.8 lb)
RS485 Output: MODBUS and proprietary communication protocol

Analyzer
Conductivity Range: 1µS/cm to 2S/cm
Resistivity Range: 10MΩ/cm to infinity
Resolution: 0.1 or 0.01
Temperature Compensation: 0 to 100°C (32 to 212°F), Automatic or Manual
Operating Temperature: 5 to 40°C (41 to 104°F)
Cell Constants Offered: 0.01, 0.1, 1, 5 or 10 cm-1

Transmitter
Analog Output: 4 to 20 mA (2), this output can be programmed for transmission
Impedance: 600 Ω
Optical Galvanic Isolation: 2000 Vac
Controller Outputs: 2 N.O. (1A/240 Vac) on/off alarm or PWM; 4 to 20 mA for PID control or retransmittion

Cells
CDE-440-001:
   Range: 0.01 µS to 2 mS in SS or Titanium, K = 0.01, 0 to 100°C (32 to 212°F), 10 kg/cm2
   Insertion Length: 54 mm (2.1")
   Thread: 316 SS, ¾NPT
CDE-440-01:
   Range: 0.1 µS to 20 mS, K = 0.1, 0 to 130°C (32 to 266°F), 10 kg/cm2
   Insertion Length: 42 mm (1.7")
   Thread: 316 SS, ¾NPT
CDE-440-1:
   Range: 0.1µS to 100 mS, K = 1, 0 to 130°C (32 to 266°F), 10 kg/cm2
   Insertion Length: 60 mm (2.4")
   Thread: 316 SS, ¾NPT
CDE-440-5:
   Range: 1 µS to 150 mS, K = 5, 0 to 130°C (32 to 266°F), 10 kg/cm2
   Insertion Length: 60 mm (2.4")
   Thread: 316 SS, ¾NPT (PVDF body)
CDE-440-01T:
   Range: 0.1 µS to 20 mS, K = 0.1, 0 to 200°C (32 to 392°F), 10 kg/cm2
   Insertion Length: 90 mm (3.5")
   Thread: 316 SS, ¾NPT
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
CDCN441
Consult Sales  
Availability: 
 
 
Conductivity/resistivity controller with relay and 4 to 20 mA outputs
Conductivity Sensors
  
CDE-440-001
AUD1,000.62
Availability: 9 weeks
 
Conductivity sensor K = 0.01, 0.01 µs to 2 ms
  
CDE-440-01
AUD1,000.00
Availability: 9 weeks
 
Conductivity sensor K = 0.1, 0.1 µs to 20 ms
  
CDE-440-1
AUD1,130.00
Availability: 9 weeks
 
Conductivity sensor K = 1, 0.1 µs to 100 ms
  
CDE-440-5
AUD1,085.00
Availability: 9 weeks
 
Conductivity sensor K = 5, 0.1 µs to 150 ms
  
CDE-440-01T
AUD1,420.00
Availability: 9 weeks
 
Conductivity sensor K = 0.1 heavy duty, 0.1 µs to 20 ms
Accessories
Click to expand/minimize a list of what others bought with theCDSA-10
CDSA-10
AUD128.41
Availability: 1 week
 
10 micromho calibration solution 940 ml (1qt)
Click to expand/minimize a list of what others bought with theCDSA-45
CDSA-45
AUD31.25
Availability: 3 weeks
 
45 micromho calibration solution 940 ml (1qt)
Click to expand/minimize a list of what others bought with theCDSA-450
CDSA-450
AUD31.25
Availability: 1 week
 
450 micromho calibration solution 940 ml (1qt)
Click to expand/minimize a list of what others bought with theCDSA-1500
CDSA-1500
AUD31.25
Availability: 1 week
 
1500 micromho calibration solution 940 ml (1qt)
Click to expand/minimize a list of what others bought with theCDSA-4500
CDSA-4500
AUD33.02
Availability: 3 weeks
 
4500 micromho calibration solution 940 ml (1qt)
Click to expand/minimize a list of what others bought with theCDSA-45000
CDSA-45000
AUD33.02
Availability: 1 week
 
45000 micromho calibration solution 940 ml (1qt)
All amounts shown in AUD
Note: Comes complete with 316 SS hardware for 51 mm (2") tube installation and wall mount brackets and operator’s manual. Sensors sold separately.
Ordering Example:  (1) CDE-440-5 Sensor K = 5 (PVDF material), AUD1,085.00
We noticed you are from the US. Visit your local site for regional offers and live support.