Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Dual Channel Conductivity/ResistivityController

CDCN-91

Dual Channel Conductivity/ResistivityController | CDCN-91

Dual Channel Conductivity/ResistivityController

AUD2,457.08 CDCN-91

CE
  • 2-Channel Input
  • Simultaneous Display
  • AC Line-Voltage or DC Powered
  • Display and/or Control: µS, mS, PPM or PPB (TDS), kohms, Mohms, % Rejection, Difference, Ratio, °C or °F
  • 3 Fully Scalable 4 to 20 mA Outputs
  • Up to 4 Programmable Relays
  • Time Delay Relay Function
  • Proportional Pulse Control Capability
  • Meets USP Requirements
  • Programmable Temperature Compensation
  • Output Simulation for Complete System Testing
  • Simple Push-Button Operation
  • 1 /4 DIN, NEMA-4X/IP65 Enclosure with Self-Healing Window
Conductivity Instrumentation - View related products

Description

The CDCN-91 series dual channel conductivity/resistivity controller is a two-channel input device equipped with three scalable 4 to 20 mA outputs and four programmable relays. A selector switch activates two open collector outputs in place of two of the relays for extraordinary output versatility. Dual input and advanced control capability, including percent rejection, difference and ratio calculations, together with the CDCE-91 series conductivity sensors listed below, form the perfect measurement and control system for water treatment applications and more. Two versions are available: one accepts AC line-voltage, the other low voltage DC for power. The four-button keypad arrangement with intuitive software design is user-friendly, and the NEMA-4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional rear cover kit.

Specifications
General
Compatible Sensors: CDCE-90 series standard conductivity/resistivity sensors
Operating Range:
Conductivity:0.055 to 400,000 µS/cm
Resistivity: 10 K½/cm to 18.26 M½/cm (0.055 to 100 µS/cm)
TDS: 0.001 to 999999 ppm or ppb (display limit)
Temperature: PT1000: -25 to 120°C (-13 to 248°F)
Accuracy:
Conductivity/Resistivity: ±2% of reading
Temperature: ±0.5°C
Power Requirements: 3-8860-AC: 100 to 240 Vac ±10%, 50-60 Hz, 20 VA 3-8860: 11 to 24 Vdc ±10% reg., 0.5A max.
Display: Alphanumeric 2 x 16 LCD
Contrast: User selected, 5 levels
Update rate: 1.5 seconds
Current Outputs: (3 each) 4 to 20 mA, isolated, fully adjustable and reversible.
Max. Loop Impedance: 150ohm @ 12V, 450ohm @ 18 V, 750ohm @ 24 V
Update Rate: Approx. 100 mS
Accuracy: ±0.03 mA @ 25°C, 24 Vdc
Open Collector Outputs: (2 each) Isolated, 50 mA sink or source, 30 Vdc max. pull-up voltage.
Operational Settings: Hi, Lo, USP, Pulse, Off
Hysteresis: User adjustable Time Delay: 0 to 6400 seconds Maximum
Pulse Rate: 400 pulses/minute
Alarm Contacts: (up to 4 each) SPDT Relays
Maximum Voltage Ratings: 5A @ 30 Vdc or 5A @ 250 Vac
Enclosure:
Rating: NEMA-4X/IP65 front and back with optional NEMA-4X Rear Cover Kit
Materials: Case: PBT Window: Polyurethane-coated polycarbonate Keypad: Sealed 4-key silicone rubber
Weight: CDCN-91AC: Approx. 581 g (20.5 oz) CDCN-91: Approx. 544 g (19.2 oz)

Please download the full product specifications for additional technical information and a complete list of all models available.
See CDCE-90-001, CDCE-90-01, CDCE-90-1, CDCE-90-10, CDCE-90-20 for a complete list of available conductivity cells.
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
Click to expand/minimize a list of what others bought with theCDCN-91
CDCN-91
AUD2,457.08
Availability: 1 week
 
Conductivity/Resistivity Controller DC Power
Click to expand/minimize a list of what others bought with theCDCN-91AC
CDCN-91AC
AUD2,480.00
Availability: 9 weeks
 
Conductivity/Resistivity Controller AC/DC Power
Conductivity Sensors
Click to expand/minimize a list of what others bought with theCDCE-90-001
CDCE-90-001
AUD725.00
Availability: 1 week
 
Conductivity Cell Constant = 0.01
Click to expand/minimize a list of what others bought with theCDCE-90-01
CDCE-90-01
AUD761.58
Availability: 1 week
 
Conductivity Cell Constant = 0.1
Click to expand/minimize a list of what others bought with theCDCE-90-1
CDCE-90-1
AUD761.58
Availability: 1 week
 
Conductivity Cell Constant = 1.0
Click to expand/minimize a list of what others bought with theCDCE-90-10
CDCE-90-10
AUD1,267.45
Availability: 15 weeks
 
Conductivity Cell Constant = 10.0
Accessories
Click to expand/minimize a list of what others bought with theFP90-4X
FP90-4X
AUD121.08
Availability: 7 weeks
 
NEMA-4X Rear Cover Kit
Click to expand/minimize a list of what others bought with theFPM-5000-LTCK
FPM-5000-LTCK
AUD146.00
Availability: 9 weeks
 
Liquid-Tight Kit for Rear Cover
Click to expand/minimize a list of what others bought with theFPM-5000-MB
FPM-5000-MB
AUD100.00
Availability: 9 weeks
 
Surface Mount Bracket
Conductivity Solutions
Click to expand/minimize a list of what others bought with theCDSA-450
CDSA-450
AUD31.25
Availability: 1 week
 
450 µmho/cm conductivity solution
Click to expand/minimize a list of what others bought with theCDSA-1500
CDSA-1500
AUD31.25
Availability: 1 week
 
1500 µmho/cm conductivity solution
Click to expand/minimize a list of what others bought with theCDSA-4500
CDSA-4500
AUD33.02
Availability: 1 week
 
4500 µmho/cm conductivity solution
All amounts shown in AUD
Note: Comes complete with operator's manual, panel mounting bracket, and panel gasket.

Conductivity electrodes are sold separately.