Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

CL510A Series

RTD Simulators | CL510A Series

RTD Simulators

AUD2,157.63 CL510A-10

CE
  • Source One or Multiple RTD Curves
  • High Accuracy
  • Easy-to-Read Backlight Display
  • Calibrate Directly in Temperature (°C or °F)
  • Compatible with All RTD Process Instruments
Precision Calibration Equipment and Ice Point References - View related products

Description

The CL510A Series can check and calibrate all your RTD instruments. Take it into the shop, plant or field without worry. It’s easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a decade box and RTD resistance tables, with the CL510A you can calibrate directly in temperature (°C and °F). Choose between a single RTD type model, CL510A-1 (Pt100, 0.00385), or a CL510A-10 for multiple RTD types.

The CL510A-10 works with a wide variety of RTD curves including Platinm 100 (alpha = 3850, 3902, 3916, 3926) and 1000 (alpha = 3850, 3750) Ω, Copper 10 and 50 Ω, Nickel 100 and 120 Ω. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL". Connect directly to RTD inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their displays.

SPECIFICATIONS (Unless otherwise indicated, all specifications are rated from a nominal 23°C (73°F), 70% RH)
Accuracy: ±(0.015% of Rdg + 0.05 Ω)
Temperature Drift: ±0.05 Ω/°C
Operating Temperature Range: -25 to 60°C (-10 to 140°F)
Relative Humidity Range, 10% ≤RH:
    ≤90%: 0 to 35°C (32 to 95°F), non-condensing
    ≤70%: 35 to 60°C (95 to 140°F), non-condensing
Size: 126 L x 69 W x 45 mm H (4.96 x 2.73 x 1.79")
Weight: 0.24 kg (8.4 oz) (including batteries)
Batteries: 4 "AA" alkaline 1.5V (included)
Battery Life: 50 hr
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 Vdc (rated for 30 sec)
Display: High contrast graphic liquid crystal display, LED backlighting for use in low lit areas

Source
Accuracy: From 1 to 10.2 mA
External Excitation Current: ±(0.015% of rdg + 0.05 Ω) Below 1 mA of External
Excitation Current: ±(0.015% of rdg + 0.01 mV/mA excitation current + 0.05 Ω)
Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω
Allowable Excitation Current Range, Steady or Pulsed/Intermittent:
    <410 Ω: 10.2 mA max
    410 to 001 Ω: 1 mA max Pulsed Excitation Current
Compatibility: DC to 0.01 second pulse width
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
Temperature Calibrator
Click to expand/minimize a list of what others bought with theCL510A-1
CL510A-1
AUD1,704.72
Availability: 1 week
 
RTD simulator, 1 Type (Pt100, 0.00385)
Click to expand/minimize a list of what others bought with theCL510A-10
CL510A-10
AUD2,157.63
Availability: 1 week
 
RTD simulator, 10 Types
Accessories
Click to expand/minimize a list of what others bought with the020-0209
020-0209
AUD186.39
Availability: 1 week
 
Rubber boot
Click to expand/minimize a list of what others bought with theSC-HH500
SC-HH500
Consult Sales  
Availability: 
 
 
Soft carrying case
All amounts shown in AUD
Note: Comes complete with 4 "AA" alkaline batteries, NIST certificate of calibration (no points), RTD wire kit with 2 red and 2 black leads with retractable shield banana plugs and spade lugs, and operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.