Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Automated Universal RTD Calibrator

CL514-PLUS

Automated Universal RTD Calibrator | CL514-PLUS

Automated Universal RTD Calibrator

AUD2,478.74 CL514-PLUS

CE
  • Source and Read Mutiple RTD Curves Plus Ω
  • Easy-to-Read Backlight Display
  • Automatically Detects 2, 3 and 4 Wire Connections
  • Calibrate Quickly With Automatic Output Stepping
  • Comes Protected With a Rugged Rubber Boot
  • Calibrate Directly in Temperature (°C or °F)
  • Compatible With All RTD Process Instruments
Precision Calibration Equipment and Ice Point References - View related products

Description

With the CL514-PLUS you can check and calibrate all your RTD instruments and measure RTD sensors. Automatic indication of connections on the display for simple hookups. Take it without worry into the shop, plant or field. It comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a decade box and RTD resistance tables, you can calibrate directly in temperature (°C and °F). The CL514-PLUS works with a wide variety of RTD curves including Platinm 100 (alpha = 3850, 3902, 3926) and 1000 (alpha = 3850, 3750) Ω, Copper 10 and 50 Ω, Nickel 100 and 120 Ω. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL" plus store any three temperatures for instant recall. Calibrate quickly with automatic output stepping. Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds. Connect directly to RTD inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their outputs or displays. Measure and trouble shoot RTD sensor connections and find broken wires. Connect your 2, 3 or 4 wire RTD sensor and the CL541-PLUS automatically measures the RTD in °C or °F.

SPECIFICATIONS (Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH)
Accuracy: ±(0.025% of Reading + 0.05 Ω)
Temperature Drift: ±0.01% of span outside of 23°C ±10°C (73°C ±18°F)
Operating Temperature Range: -25 to 60°C (-10 to 140°F)
Relative Humidity Range: 10% ≤RH ≤90% (0 to 35°C), non-condensing 10% ≤RH ≤70% (35 to 60°C), non-condensing
Dimensions: 143 L x 76.2 W x 40.64 mm H (5.63 x 3.00 x 1.60")
Weight: 12.1 oz (including boot and batteries)
Batteries: 4 "AA" Alkaline 1.5V (included)
Battery Life: 50 Hours
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 V dc (rated for 30 seconds)
Display: High contrast graphic liquid crystal display. LED backlighting for use in low lit areas.
READ
Excitation Current:
0.5 mA nominal
Normal Mode Rejection: 50/60 Hz, 50 dB
Common Mode Rejection: 50/60 Hz, 120 dB
Source
Accuracy From 1 to 10.2 mA External Excitation Current:
±(0.025% of Reading + 0.05 Ω) Below 1 mA of External Excitation
Current: ±(0.025% of Reading + 0.025 mV/ mA Excitation Current + 0.05 Ω)
Resistance Ranges: 0.00 to 410.00, 410.1 to 2001.0 Ω Allowable Excitation Current Range:
<410 Ω: 10.2 mA max; steady or pulsed/intermittent
410 to 2001 Ω: 1 mA max; steady or pulsed/intermittent Pulsed Excitation Current
Compatibility: DC to 0.01 second pulse width
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
CL514-PLUS
AUD2,478.74
Availability: 1 week
 
Automated universal RTD calibrator
Accessories
Click to expand/minimize a list of what others bought with theSC-530
SC-530
Consult Sales  
Availability: 
 
 
Soft carrying case
All amounts shown in AUD
Note: Comes complete with rubber boot, 4 “AA” alkaline batteries, NIST certificate of calibration, carrying case, RTD wire kit with 2 red and 2 black leads with retractable shield banana plugs and spade lugs and operator’s manual.
Ordering Example: (1) CL514-PLUS Automated universal RTD calibrator, AUD2,478.74
We noticed you are from the US. Visit your local site for regional offers and live support.