The CN76000 1/16 DIN controllers provide economical
control for a wide variety of processes, including
heating, cooling, and heat/cool. When used with the
proper transmitters, these devices can also control
pressure, flow, humidity, motion, or pH. The front
panel is NEMA 2, 3R, and 12 rated for waterproof
protection and is corrosion resistant.
The sophisticated design of the CN76000 incorporates
the latest microprocessor and surface mount
technology, compressing an unprecedented number of
standard features into a compact 1/16 DIN package. The
user can program control functions from the front
panel; input types are DIP switch selectable. Multiple
tuning modes allow the user to select from 3 standard
tuning presets, manual tuning, or autotuning.
Standard features include self-diagnosis with fault
indication. Non-volatile memory retains all process
parameters when power is off, without battery backup.
Settings for the optional alarm are configurable. The
alarm action may be defeated on startup, or until the
process value exceeds the alarm setpoint. The power
interrupt feature will reset on power-up if the alarm
condition no longer exists.
Other standard features include min/max storage and
display, auto/manual control, percent output indication,
ramp and soak operation, 4 user-selectable security
levels with password protection, and jumper-selected
5 Vdc pulse output to drive external solid state relays.
Optional features include RS485 communications,
process recorder output.
Note: CE not available with -485 commmunications option
† All amounts shown in AUD Note: Each unit supplied with mounting bracket and complete operator's manual. *These outputs are logic jumper selectable between relay and DC pulse, or between DC pulse and AC SSR. Ordering Example: (1) CN76133 CN76000 controller with dual relay/DC pulse outputs, alarm, AUD1,957.10
Part Number Builder
Build Your Part Number Below
Option Descriptions:
(1)
Alarm select from: 0 for Standard unit 1 for Alarm unit
(2)
Output select from: 30 for Relay/DC Pulse 20 for DC pulse/AC SSR 50 for 0 to 20 mA 60 for 0 to 10 Vdc 33 for Dual Relay/DC pulse outputs 22 for Dual DC pulse/AC SSR 53 for Output 1 0 to 20 mA and Output 2 Relay/pulse 63 for Output 1 0 to 10 Vdc and Output 2 Relay/DC pulse
(3)
Additional Options select from: Nothing(leave field blank) for None -PV for Scalable recorder and output 0 to 10 Vdc -485A for RS485 communications
Note: All combinations may not be valid, check spec sheet for valid part numbers.