  • 700 V I/O Isolation
  • 1100 V Line Isolation
  • Power for Four 350 Ohm Load Cells, Fixed 10 V or Variable 5 to 10 Vdc
  • Adjustable Gain and Offset
  • Large Tare Offset Adjustment
  • 6 Wire Bridge Connections
  • Voltage or Current Output Models
Accessories - View related products

Description

The DMD-470 Series bridge amplifiers are ac powered signal conditioning modules with triple isolated voltage or current outputs for load cells, bridge type sensors and strain gages. Both models have dual zero/tare functions. Zero is used for normal bridge balance and the tare feature allows up to 68% of the input to be offset and still achieve full output span. The DMD-475 has an isolated voltage output; the DMD-476 is similar, but has an isolated 4 to 20 mA output. Both models have input ranges of 5 to 50 mV for a full scale output (0-10 V or 4-20 mA).

SPECIFICATIONS
Common
Power: 115 Vac ±10 Vac standard or 220 Vac ±10% 50/60 Hz optional
Isolation:
    AC Line: 1100 Vrms, 60 pF
    Input to Output: 700 Vdc and 60 pF
Operating Temperature: -25 to 55°C (-13 to 131°F)
Storage Temperature: -25 to 85°C (-13 to 185°F)
Weight: 510 g (18 oz)
Size: 96 L x 51 W x 73 mm H (3.75 x 2 x 2.87")

Bridge Supply
Voltage Range:
5 to 10 Vdc
Current Output: 120 mA max
Line and Load Regulation: 0.02% max
Output Noise: 1 mVrms max (120 Hz)
Temp Coefficient: 60 ppm @ 10V, 100 ppm max

DMD-475 (Voltage Output)
Gain Range:
200 to 2000
Input Range for 10V Output: 5 to 50 mV
Linearity: ±0.005% FS
Temperature Stability: 0.005%/°C
Tare Adjustment: -3 to 25 mV
Input Resistance: 1000 MΩ
Output Zero Adjust: 0 to 2V
Output Range: -3 to 10 Vdc
Output Current: 5 mA maximum
Dynamic Response: DC to -3 dB = 10 Hz, 2 pole
Response Time: 10 to 90% = 35 ms

DMD-476 (4 to 20 mA Transmitter)
Output:
4 to 20 mA, 0 to 20 mA
Input Range for 16 mA Span: 5 mV min, 50 mV max
Linearity: ±0.01%
Zero Adjust: 0 to ±12 mA
Temperature Stability: 0.005%/°C
Tare Adjustment: -3 to 25 mV equals 80% of 3 mV/V cell
Input Impedance: 1000 MΩ
Common-Mode Rejection: 100 dB
Common-Mode Input Voltage: 5V
Output Zero Adjust: 0 or 4 mA
Output Range: 4 to 20 mA or 0 to 20 mA
Compliance Voltage: -1 to 20V
Dynamic Response: DC to -3 dB = 10 Hz, 2 pole
Response Time: 10 to 90% = 35 ms
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
DMD-475
Consult Sales  
Availability: 
 
 
Isolated voltage output (0 to 10 Vdc) amplifier/signal conditioner module
  
DMD-475-220V
Consult Sales  
Availability: 
 
 
Isolated 220 Vac powered DMD-475
  
DMD-476
Consult Sales  
Availability: 
 
 
Isolated current output (4 to 20 mA) amplifier/signal conditioner module
  
DMD-476-220V
Consult Sales  
Availability: 
 
 
Isolated 220 Vac powered DMD-476
  
DMD-476-DC
Consult Sales  
Availability: 
 
 
Isolated current output (4 to 20 mA) amplifier/signal conditioner module, 10-36 Vdc powered
Accerrories
Click to expand/minimize a list of what others bought with theDIN400
DIN400
Consult Sales  
Availability: 
 
 
DIN Rail Mounting Kit
  
POWER CORD-SE
AUD21.43
Availability: 4 weeks
 
AC Power cord with stripped end termination
All amounts shown in AUD
Ordering Example: (1) DMD-475 Isolated voltage output (0 to 10 Vdc) amplifier/signal conditioner module, AUD1,230.00

Product Manuals:

Download DMD-475 - Bridgesensor AC Powered Signal Conditioner
Download DMD-476 - Bridgesensor AC Powered Signal Conditioner
Download DMD-476-DC - DC Powered Signal Conditioner
We noticed you are from the US. Visit your local site for regional offers and live support.