ALARM MODULE - DC INPUT TO SINGLE ALARM

DMD1080 Series

ALARM MODULE - DC INPUT TO SINGLE ALARM  ISOLATED, FIELD CONFIGURABLE, DIN RAIL | DMD1080 Series

AUD588.91 DMD1080

  • Easy Field Setup --- One Minute Setup for 24 Input Ranges
  • Switch Selectable Relay Configuration
  • Removable Plugs for Faster Installation
  • Input Tracker and Alarms Status LEDs
  • Full 1200V Isolation
  • Alarm Test/Reset Button
  • Built-In Loop Power Supply for Sink/Source Input
Instrumentation for Pressure and Strain Measurements - View related products

Description

The DMD1080 accepts a DC voltage or current input and provides visual alarm indication and alarm relay contact outputs. 15 voltage and 9 current input ranges can be field configured via external rotary and slide switches. Offset ranges such as 1 to 5 Vdc and 4 to 20 mAdc are also included. Heavy-duty relay contacts allow the module to directly control high capacity loads. Front accessible potentiometers are used to adjust the alarm setpoint from 0 to 100% and the deadband from 1 to 100%. The unit provides a single setpoint adjustment of the two DPST relay contacts. The alarm output can be field configured for HI or LO operation, latching or non-latching, and normal or reverse acting.

Specifications
Input Ranges: 24 field selectable ranges via switch settings
    Voltage: 0-50 mV to 0-10 Vdc
    Bipolar Voltage: ±5 Vdc or ±10 Vdc
    Current: 0-1 mADC to 0-20 mADC, 4-20 mADC
Input Impedance and Burden:
    Voltage: 250 kΩ minimum
    Current: 50 Ω typical
    Voltage Burden: 1 Vdc at 20 mA current input
Isolation:
    1200V Isolation: power to input 600 Vac or 600 Vdc common mode protection
Input Loop Power Supply: 15 Vdc ±10%, 25 mADC maximum ripple, less then 10 mV rms may be wired for sinking or sourcing mA input
Relay Output: Single setpoint dual DPST contacts, field configurable; 2 Form A (NO) and Form B (NC) contact sets (8 terminals) may be wired for C Form operation
Relay Contact Ratings:
    8 Amps @ 240 Vac resistive load
    5 Amps @ 240 Vac inductive load
    8 Amps @ 30 Vdc resistive load
    3.5 Amps @ 30 Vdc inductive external contact protection such as a RC snubber is recommended for inductive loads
Set Point: 12 turn potentiometer adjustable from 0 to 100% of span
Deadband: 12 turn potentiometer adjustable from 1 to 100% of span
Response Time: 70 milliseconds typical
Functional Test/Reset Button: Toggles relay to opposite state when pressed; resets latching relay if latching relay mode is selected
Ambient Temperature Range and Stability:-10 to 60°C (14 to 140°F) operating ambient; better than 1% of span over operating temperature range; better than 0.02% of span per °C
Power: 60 to 265 Vac, 50/60 Hz or 85 to 300 Vdc, 2W maximum
    DC Versions: 9 to 30 Vdc or 10 to 32 Vac, 50/60 Hz, 2W maximum
Housing: Mounts to standard 35 mm DIN rail, IP40 rating
Connectors: Four 4-terminal removable connectors 14 AWG maximum wire size
Dimensions: 22.5 W x 117 H x 122 mm D (0.89 x 4.62 x 4.81")
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
DMD1080
AUD588.91
Availability: 6 weeks
 
Standard power input, DC input alarm module, isolated, field configurable
DMD1080-DC
AUD555.00
Availability: 6 weeks
 
Low power input, DC input alarm module, isolated, field configurable
All amounts shown in AUD
Note: Comes complete with operator’s manual.