Note: Comes complete with 24 Vdc power supply, 1.8 m (6') cable, 8 pin male mini DIN connector, operator’s manual and NIST certificate.
††Portable versions "-B" have an integral battery compartment and come complete with 24 Vdc power supply, 1.8m (6') cable, 8 pin male mini DIN connector, operator's manual, NIST certificate, and 9V battery installed. Portable version is not available on models with 4 to 20 mA output.
Units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.
Calibrations done at ambient (25°C/77°F) temperature only.
To replace the standard RS232 communications with RS485, add suffix "-RS485" to the model number, add $120 to the price.
Standard output is scaled to the mass flow rate. For volumetric flow rate as standard output add "-VOL" to the model number.
Optional secondary output are scaled the same as the primary output. For a different secondary output scale add suffix "-T" for temperature or suffix "-P" for pressure, no additional cost.
Add "-SCFH" to model number for units scaled in SCFH, no additional charge. Specify required range in SCFH.
For totalizer option, add suffix "-TOT" to the model number, add $120 to the price. Please specify resolution. This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.
High accuracy calibrations to ±0.5% of full scale are available on models having a minimum full scale range of 10 SCCM or greater. For a high accuracy calibration add suffix "-HACAL" to the model number, add $400 to the price.
For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.
Ordering Example: (1) FMA1613A Mass Flowmeter, 3/4, AUD4,962.00
Part Number Builder
Build Your Part Number Below
Option Descriptions:
(1)
Max Flow select from:01 for 0.5 SCCM
02 for 1 SCCM
14 for 2 SCCM
15 for 5 SCCM
03 for 10 SCCM
16 for 20 SCCM
04 for 50 SCCM
17 for 100 SCCM
18 for 200 SCCM
19 for 500 SCCM
20 for 1 SLM
05 for 2 SLM
06 for 5 SLM
07 for 10 SLM
08 for 20 SLM
09 for 50 SLM
10 for 100 SLM
11 for 250 SLM
12 for 500 SLM
13 for 1000 SLM
21 for 1500 SLM
22 for 2000 SLM
23 for 3000 SLM
(2)
Output select from:Nothing(leave field blank) for None
-I for 4 to 20 mA output
-I2 for Two 4 to 20 mA outputs
-V2 for Two 0 to 5V Outputs
-I2-T for Two 4 to 20 mA outputs second output for temperature
-V2-T for Two 0 to 5V outputs second output for temperature
-I2-P for Two 4 to 20 mA outputs second output for pressure
-V2-P for Two 0 to 5V outputs second output for pressure
-VOL for Volumetric flow rate as standard output
(3)
Portable Version select from:Nothing(leave field blank) for Standard
-B for Portable version of the meter (not available on models with 4 to 20 mA output)
(4)
Input select from:Nothing(leave field blank) for 0 to 5V
-IN for 4 to 20 mA input
(5)
RS485 select from:Nothing(leave field blank) for RS232
-RS485 for RS485
(6)
SCFH select from:Nothing(leave field blank) for Standard
-SCFH for Units scaled in SCFH
(7)
Totalizer select from:Nothing(leave field blank) for Standard
-TOT for Totalizer
Note: All combinations may not be valid, check spec sheet for valid part numbers.