Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Industrial Air Velocity Transmitter with Built-In Relay

FMA900A

Industrial Air Velocity Transmitter with Built-In Relay | FMA900A

Industrial Air Velocity Transmitter with Built-In Relay

AUD996.49 FMA902A-MA

  • Air Velocity Range Up to 10,000 FPM (50.8 m/sec)
  • 2% Full Scale Accuracy
  • Hot Wire Air Velocity Sensor Design
  • Two Sensor Probe Configurations: Fixed Mount and Remote Probe
  • 250 msec Response Time
  • Adjustable High Alarm Set Point
  • One SPST Relay Contact Closure with Red LED Indication
  • Linear 0 to 5 Vdc or 4 to 20 mA Analog Output
  • Used in HVAC Monitoring, Exhaust/Ventilation Hoods
Electronic Mass Flow Meters & Controllers - View related products

Description

The FMA900A Series measures air velocity and provides an analog output proportional to the air flow, and one SPST relay contact closure for high alarm operation. The alarm set point is adjustable from 0 to 100% of the air flow range. The unit comes with one green power LED, and one red LED for alarm indication. The FMA900A Series are used in research and development labs, HVAC applications, exhaust/ ventilation hoods and other manufacturing processes. The sensor probe comes in two configurations, fixed mount 305 mm (12") probe and remote 305 mm (12") probe with 4.5 m (15') of shielded cable.

SPECIFICATIONS
Air Velocity Range:
0 to 500, 0 to 1000, 0 to 2000, 0 to 5000, 0 to 10,000
Accuracy: 2% of FS
Air Velocity Probe: 6 OD x 305 mm L (¼ OD x 12") stainless steel, or remote probe
High Alarm Set Point: Adjustable from 0 to 100% of air flow range
Alarm Indication: Red LED on the back plate
Alarm Deadband: 5% of FS
Relay: One 12V SPST NO relay
Contact Rating: 10A @ 24 Vdc
Analog Output: 0 to 5 Vdc, 4 to 20 mA
Operating Ambient Temperature:
    Sensor Probe: -40 to 93°C (-40 to 199°F)
    Electronic Case: 0 to 50°C (32 to 122°F)
Power Indicator: Green LED
Power: 15 to 24 Vdc @ 200 mA
Dimensions: 89 H x 51 W x 32 mm D (3.5 x 2 x 1.25")
Weight: 160 g (5.6 oz)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
FMA904R-V1
AUD1,120.49
Availability: 7 weeks
 
Air velocity transmitter with built-in relay, 0 to 5000 FPM, remote probe, 0 to 5 Vdc output,
FMA904A-MA
AUD996.49
Availability: 7 weeks
 
Air velocity transmitter with built-in relay, 0 to 5000 FPM, fixed probe, 4 to 20 mA output
FMA902R-V1
AUD1,120.49
Availability: 7 weeks
 
Air velocity transmitter with built-in relay, 0 to 1000 FPM, remote probe, 0 to 5 Vdc output
FMA901R-MA
AUD1,073.65
Availability: 7 weeks
 
Air velocity transmitter with built-in relay, 0 to 500 FPM, remote probe, 4 to 20 mA output
FMA902A-MA
AUD996.49
Availability: 7 weeks
 
Air velocity transmitter with built-in relay, 0 to 1000 FPM, fixed probe, 4 to 20 mA output
FMA905A-V1
AUD944.50
Availability: 7 weeks
 
Air velocity transmitter with built-in relay, 0 to 10,000 FPM, fixed probe, 0 to 5 Vdc output
All amounts shown in AUD
Note: Comes complete with 305mm (12") long sensor probe or remote probe, and operator's manual.
Ordering Example: (1) FMA904R-V1 Air velocity transmitter with built-in relay, 0 to 5000 FPM, remote probe, 0 to 5 Vdc output, AUD1,120.49

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Transmitter Range (m/sec) select from:
900 for 0 to 200 (0 to 1.02)
901 for 0 to 500 (0 to 2.54)
902 for 0 to 1000 (0 to 5.08)
903 for 0 to 2000 (0 to 10.16)
904 for 0 to 5000 (0 to 25.4)
905 for 0 to 10000 (0 to 50.8)

(2) Probe select from:
A for Fixed Probe
R for Remote Probe

(3) Output select from:
-V1 for 0 to 5 Vdc
-MA for 4 to 20 mA

(4) Probe Length select from:
Nothing(leave field blank) for Standard
-S for 95 mm (3.75in) short probe
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.