The FPD3000 Series positive
displacement flowmeters are
affordable and accurate. One
primary feature is the ability to
maintain consistent accuracy
despite changing viscosity
conditions. The meter’s solid
construction and excellent dynamic
response are well suited to the
measurement of fuels and oils as
well as other non-abrasive
lubricating fluids. Since there is
no need for straight run piping
upstream or downstream of the
flowmeter, the FPD3000 flowmeters
are simple to use and to install. The
meter has good resolution and high
accuracy at low flow rates.
Specifications Accuracy: ±0.5% of reading Repeatability: ±0.03% Fitting Type: NPT: Female BSP: “-BSP” option DIN: “-DIN” option JIS: “-JIS” option ANSI: “-ANSI” option Hall-Effect Sensor Power: 4.5 to 24 Vdc (7.5 mA) Reed Sensor Power: 30 Vdc (500 mA) Output Options: Pulse Output: Standard 4 to 20 mA Transmitter: “-D-A” option; no output on battery powered “-D” model FPD3003 FPD3005D-A Both models shown smaller than actual sizer. Display: 7-digit/12 mm (0.47") upper, 7-digit/7 mm (0.28") lower all “-D” options Rate: User defined Total: Resettable Acc-Total: Non-resettable Minimum Viscosity: 1cPs Maximum Viscosity: 1000 cPs standard Maximum Pressure: See chart on page F-3 Strainer Size: See chart on next page Mounting: Shafts must be in a horizontal plane Electrical Connections: 2 x 12 mm (0.08 x 0.47"), fittings included “-D-A” option Cable Length: 1 m (3') stripped ends non-display models Mounting: Pipe Power: 4 to 20 mA, “-D-A” models 18 to 30 Vdc display, “-D” models 3 Vdc lithium battery (included) Liquid Temperature: -40 to 80°C (-40 to 176°F) Materials Body: Aluminum Enclosure: Polypropylene Seals: FKM Fasteners: Stainless steel Cable Insulation: PVC Enclosure: NEMA 6 (IP67)
† All amounts shown in AUD Note: Comes complete with 3 Vdc lithium battery and operator’s manual.
For units with BSP connections, add suffix “-BSP” to the model number; no additional charge.
For units with DIN flanges, add suffix “-DIN” to the model number; add $250 for 1", add $275 for 1 1/2", and add $410 for 2" to price.
For units with JIS flanges, add suffix “-JIS” to the model number; add $250 for 1", add $275 for 1 1/2", and add $410 for 2" to price.
For units with ANSI flanges, add suffix “-ANSI” to the model number; add $250 for 1", add $275 for 1 1/2", and add $410 for 2" to price.
For units with high viscosity rotors (up to 1,000,000 cps), add suffix “-HV” to the model number; add $560 to price.
This product page contains items that either have a Lithium Battery installed in the equipment or have a Lithium Battery packed with the equipment. These items as being regulated for air transportation. The following applies:
• No FX1D, FX2D or FX3D can be used as a ship method.
• Only UPS1, UPS2 or UPS3 is authorized.
• For International shipments UPS and DHL can be used. For DHL internationally – Omega only has permission to ship Lithium Batteries no other Hazardous Material.