Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Positive Displacement Flow Meter for Corrosive Liquids

FPD3100

Positive Displacement Flow Meter for Corrosive Liquids | FPD3100

Positive Displacement Flow Meter for Corrosive Liquids

CE
  • PPS Body
  • Temperatures up to 80ºC (176ºF)
  • NPT or BSP Threads
Turbine, Paddle Wheel & Positive Displacement Flow Meters - View related products

Description

The FPD3100 Series positive displacement flowmeters are affordable and accurate. One primary feature is the ability to maintain consistent accuracy despite changing viscosity conditions. The meter’s solid construction and excellent dynamic response are well suited to the measurement of many corrosives as well as other non-abrasive fluids. Since there is no need for straight run piping upstream or downstream of the flowmeter, the FPD3100 flowmeters are simple to use and to install. The meter has good resolution and high accuracy at low flow rates.

Specifications
Accuracy: ±0.5% of reading
Repeatability: ±0.03%
Fitting Type:
    NPT: Female
    BSP: “-BSP” option
Hall-Effect Sensor Power: 4.5 to 24 Vdc (7.5 mA)
Reed Sensor Power: 30 Vdc (500 mA)
Output Options:
    Pulse Output: Standard NPN
    4 to 20 mA Transmitter: “-D-A” option; no output on battery powered “-D” model
Display: 7-digit/12 mm (0.47") upper, 7-digit/7 mm (0.28") lower all “-D” options
    Rate: User defined
    Total: Resettable
    Accumulated-Total: Non-resettable FPD3105
Minimum Viscosity: 1cPs
Maximum Viscosity: 1000 cPs standard
Maximum Pressure: See chart on next page
Strainer Size: See ordering chart on next page
Mounting: Shafts must be in a horizontal plane
Electrical Connections: 2 x 12 mm (0.08 x 0.47"), fittings included “-D-A” option
Cable Length: 1 m (3') stripped ends, non-display models
Mounting: Pipe
Power: 4 to 20 mA, “-D-A” models 18 to 30 Vdc display, “-D” models 3 Vdc lithium battery (included)
Liquid Temperature: -40 to 80°C (-40 to 176°F), -20 to 60°C (-4 to 140°F) for display models
Materials
    Body and Rotors: PPS
    Seals: FFKM, FEP (FPD3105)
    Fasteners: Stainless steel
    Cable Insulation: PVC
    Shaft: Hastelloy C
Enclosure: NEMA 6 (IP67)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
FPD3102
AUD1,770.00
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range: <5 cPs, 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi (Kpa)75 (500)
FPD3102-D
AUD3,614.59
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range: <5 cPs, 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi (Kpa)75 (500)w/display
FPD3102-D-A
AUD4,558.61
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range: <5 cPs, 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi (Kpa)75 (500) w/display and analog output
FPD3103
AUD1,930.00
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range: <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi (Kpa) 75 (500)
FPD3103-D
AUD3,775.00
Availability: 1 week
 
Port Size 1⁄4", Flow Range: <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi (Kpa) 75 (500) w/display
FPD3103-D-A
AUD4,715.00
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range: <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi (Kpa) 75 (500) w/display and analog output
FPD3105
AUD2,562.83
Availability: 7 weeks
 
Port Size 1", Flow Range: <5 cPs, 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi (Kpa) 150 (1000)
FPD3105-D
AUD4,405.00
Availability: 7 weeks
 
Port Size 1", Flow Range: <5 cPs, 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi (Kpa) 150 (1000) w/display
FPD3105-D-A
AUD5,345.00
Availability: 7 weeks
 
Port Size 1", Flow Range: <5 cPs, 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi (Kpa) 150 (1000) w/display and analog output
All amounts shown in AUD
Note: Comes complete with lithium battery (-D) and operator’s manual. For units with a battery powered digital display add “-D” to the model number, for an additional charge. For units with a DC powered digital display and 4 to 20 mA output add “-D-A” to the model number, for an additional charge. For units with BSP connections add “-BSP” to the model number, no additional charge.

Product Manuals:

Download Oval Gear Flowmeters for use with Corrosive Chemicals
Download Digital Displays with Analog Output Options
We noticed you are from the US. Visit your local site for regional offers and live support.