Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Positive Displacement Flow Meter for solvents

FPD3300

Positive Displacement Flow Meter for solvents | FPD3300

Positive Displacement Flow Meter for solvents

CE
  • Aluminum Body
  • FEP Seals
  • Stainless Steel Rotors
  • Temperatures up to 80ºC (176ºF)
  • NPT or BSP Threads
  • DIN, JIS or ANSI Connection (Available on 1" and Larger Sizes)
Turbine, Paddle Wheel & Positive Displacement Flow Meters - View related products

Description

The FPD3300 Series positive displacement flowmeters are affordable and accurate. One primary feature is the ability to maintain consistent accuracy despite changing viscosity conditions. The meter’s solid construction and excellent dynamic response are well suited to the measurement of many solvents as well as other non-abrasive lubricating fluids. Since there is no need for straight run piping upstream or downstream of the flowmeter, the FPD3300 flowmeters are simple to use and to install. The meter has good resolution and high accuracy at low flow rates.

Specifications
Accuracy: ±0.5% of reading
Repeatability: ±0.03%
Fitting Type:
    NPT: Female
    BSP: “-BSP” option
    DIN: “-DIN” option
    JIS: “-JIS” option
    ANSI: “-ANSI” option
Hall-Effect Sensor Power: 4.5 to 24 Vdc (7.5 mA)
Reed Sensor Power: 30 Vdc (500 mA)
Output Options:
    Pulse Output: Standard
    4 to 20 mA Transmitter: “-D-A” option; no output on battery powered “-D” model
Display: 7-digit/12 mm (0.47") upper, 7-digit/7 mm (0.28") lower all, “-D” options
    Rate: User defined
    Total: Resettable
    Accumulated-Total: Non-resettable
Minimum Viscosity: 1 cPs
Maximum Viscosity: 1000 cPs standard
Maximum Pressure: See chart on page F-3
Strainer Size: See chart on next page
Mounting: Shafts must be in a horizontal plane
Electrical Connections: 2 x 12 mm (0.08 x 0.47"), fittings included “-D-A” option
Cable Length: 1 m (3') stripped ends non-display models
Mounting: Pipe
Power: 4 to 20 mA, “-D-A” models 18 to 30 Vdc display, “-D” models 3 Vdc lithium battery (included)
Liquid Temperature: -40 to 80°C (-40 to 176°F)
Materials
    Body: Aluminum
    Enclosure: Polypropylene
    Seals: FEP
    Rotors: Stainless steel
    Fasteners: Stainless steel
    Cable Insulation: PVC
Enclosure: NEMA 6 (IP67)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
FPD3302
AUD1,904.73
Availability: 1 week
 
Port Size 1⁄4", Flow Range <5 cPs 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi 1000 Kpa(6895)
FPD3302-D
AUD3,195.00
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range <5 cPs 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi 1000 Kpa(6895) w/display
FPD3302-D-A
AUD4,110.00
Availability: 1 week
 
Port Size 1⁄4", Flow Range <5 cPs 2 to 100 LPH (0.5 to 26 GPH), >5 cPs 0.5 to 100 LPH (0.13 to 26 GPH), Maximum Pressure psi 1000 Kpa(6895) w/display and analog output
FPD3303
AUD1,880.00
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi 1001 Kpa(6895)
FPD3303-D
AUD3,275.00
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi 1001 Kpa(6895) w/display
FPD3303-D-A
AUD4,188.34
Availability: 7 weeks
 
Port Size 1⁄4", Flow Range <5 cPs 25 to 500 LPH (6.6 to 132 GPH), >5 cPs 15 to 500 LPH (4 to 132 GPH), Maximum Pressure psi 1001 Kpa(6895) w/display and analog output
FPD3304
AUD3,145.00
Availability: 7 weeks
 
Port Size 1⁄2", Flow Range <5 cPs 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs 2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi 2000 Kpa(13790)
FPD3304-D
AUD4,435.00
Availability: 7 weeks
 
Port Size 1⁄2", Flow Range <5 cPs 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs 2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi 2000 Kpa(13790) w/display
FPD3304-D-A
AUD5,350.00
Availability: 7 weeks
 
Port Size 1⁄2", Flow Range <5 cPs 3 to 25 LPM (0.8 to 6.6 GPM), >5 cPs 2 to 30 LPM (0.5 to 8 GPM), Maximum Pressure psi 2000 Kpa(13790) w/display and analog output
FPD3334
AUD3,840.00
Availability: 7 weeks
 
Port Size 3⁄4", Flow Range <5 cPs 8 to 70 LPM (2 to 18.5 GPM), >5 cPs 3 to 80 LPM (0.8 to 21 GPM), Maximum Pressure psi 2001 Kpa(13790)
FPD3334-D
AUD5,130.00
Availability: 7 weeks
 
Port Size 3⁄4", Flow Range <5 cPs 8 to 70 LPM (2 to 18.5 GPM), >5 cPs 3 to 80 LPM (0.8 to 21 GPM), Maximum Pressure psi 2001 Kpa(13790) w/display
FPD3334-D-A
AUD6,045.00
Availability: 1 week
 
Port Size 3⁄4", Flow Range <5 cPs 8 to 70 LPM (2 to 18.5 GPM), >5 cPs 3 to 80 LPM (0.8 to 21 GPM), Maximum Pressure psi 2001 Kpa(13790) w/display and analog output
FPD3305
AUD4,670.00
Availability: 7 weeks
 
Port Size 1", Flow Range <5 cPs 10 to 100 LPM (2.6 to 26 GPM),>5cPs 6 to 120 LPM (1.6 to 32 GPM), Maximum Pressure psi 2002 Kpa(13790)
FPD3305-D
AUD5,960.00
Availability: 7 weeks
 
Port Size 1", Flow Range <5 cPs 10 to 100 LPM (2.6 to 26 GPM),>5cPs 6 to 120 LPM (1.6 to 32 GPM), Maximum Pressure psi 2002 Kpa(13790) w/display
FPD3305-D-A
AUD6,875.00
Availability: 7 weeks
 
Port Size 1", Flow Range <5 cPs 10 to 100 LPM (2.6 to 26 GPM),>5cPs 6 to 120 LPM (1.6 to 32 GPM), Maximum Pressure psi 2002 Kpa(13790) w/display and analog output
FPD3306
AUD6,550.00
Availability: 7 weeks
 
Port Size 11⁄2", Flow Range <5 cPs 15 to 235 LPM (4 to 62 GPM), >5 cPs 10 to 250 LPM (2.6 to 66 GPM), Maximum Pressure psi 1200 Kpa(8274)
FPD3306-D
Consult Sales  
Availability: 
 
 
Port Size 11⁄2", Flow Range <5 cPs 15 to 235 LPM (4 to 62 GPM), >5 cPs 10 to 250 LPM (2.6 to 66 GPM), Maximum Pressure psi 1200 Kpa(8274) w/display
FPD3306-D-A
AUD8,755.00
Availability: 7 weeks
 
Port Size 11⁄2", Flow Range <5 cPs 15 to 235 LPM (4 to 62 GPM), >5 cPs 10 to 250 LPM (2.6 to 66 GPM), Maximum Pressure psi 1200 Kpa(8274) w/display and analog output
FPD3307
AUD11,900.00
Availability: 1 week
 
Port Size 2", Flow Range <5 cPs 15 to 500 LPM (4 to 130 GPM), >5 cPs 16 to 500 LPM (4 to 130 GPM), Maximum Pressure psi 1001 Kpa(6895)
FPD3307-D
Consult Sales  
Availability: 
 
 
Port Size 2", Flow Range <5 cPs 15 to 500 LPM (4 to 130 GPM), >5 cPs 16 to 500 LPM (4 to 130 GPM), Maximum Pressure psi 1001 Kpa(6895) w/display
FPD3307-D-A
AUD14,110.00
Availability: 1 week
 
Port Size 2", Flow Range <5 cPs 15 to 500 LPM (4 to 130 GPM), >5 cPs 16 to 500 LPM (4 to 130 GPM), Maximum Pressure psi 1001 Kpa(6895) w/display and anal;og output
FPD3308
AUD13,905.00
Availability: 1 week
 
Port Size 3", Flow Range <5 cPs 60 to 600 LPM (15.8 to 158 GPM), >5 cPs 20 to 733 LPM (5.3 to 193 GPM), Maximum Pressure psi 175 Kpa(1206)
FPD3308-D
Consult Sales  
Availability: 
 
 
Port Size 3", Flow Range <5 cPs 60 to 600 LPM (15.8 to 158 GPM), >5 cPs 20 to 733 LPM (5.3 to 193 GPM), Maximum Pressure psi 175 Kpa(1206) w/display
FPD3308-D-A
AUD16,115.00
Availability: 7 weeks
 
Port Size 3", Flow Range <5 cPs 60 to 600 LPM (15.8 to 158 GPM), >5 cPs 20 to 733 LPM (5.3 to 193 GPM), Maximum Pressure psi 175 Kpa(1206) w/display and analog output
All amounts shown in AUD
Note: Comes complete with lithium battery and operator’s manual. For units with a battery powered digital display add “-D” to the model number, for an additional charge. For units with a DC powered digital display and 4 to 20 mA output add “-D-A” to the model number, for an additional charge. For units with BSP connections add “-BSP” to the model number, no additional charge. For units with DIN flanges add “-DIN” to the model number, for an additional charge (1" and larger only). For units with JIS flanges add “-JIS” to the model number, for an additional charge (1" and larger only). For units with ANSI flanges add “-ANSI” to the model number, for an additional charge (1" and larger only). For units with high viscosity rotors (Up to 1,000,000 cps), add “-HV” to the model number, for an additional charge.

Product Manuals:

Download Oval Gear Flowmeter w/Pulse Output or Digital Display
Download 12mm LC Digital Display with Analog Output Options
We noticed you are from the US. Visit your local site for regional offers and live support.