Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

Diaphragm-Type Injection Metering Pumps

FPUD1100, FPUDM1100, FPUDV1100, FPUDVM Series

Diaphragm-Type Injection Metering Pumps | FPUD1100, FPUDM1100, FPUDV1100, FPUDVM Series

Diaphragm-Type Injection Metering Pumps

  • Large Outlet Flowrate up to 360 GPD/1363 Liters per Day
  • High Outlet Pressure Capability of 150 PSIG (10.4 bar) (Most Models)
  • Easy Access, Front Mounted Mechanical Feed Rate Adjustment
  • Ball Bearing Supported Motor Drive Shaft
  • Permanently Lubricated Ball Bearing Motor
  • Digital Electronic Feed Rate Control Available
  • 20:1 Adjustment Turn Down Ratio (FPUD1000 Basic Model Only)
  • 4000:1 Adjustment Turn Down Ratio (Digital Models)
  • Pump Service Inpection Warning Timer (Digital Models)
  • Acceptable for Indoor Use [NEMA 3R (IP14)]
Pumps & Mixers - View related products

Description

The FPUD1000 Series are positive displacement metering pumps. The FPUD1000 Series is designed to inject chemicals into piping systems and is capable of injecting against a high system pressure up to 150 psi (10.4 bar). All models are equipped with a front mounted mechanical flow rate adjustment knob.

SPECIFICATIONS
Max Working Pressure: 10.3 bar (150 psig)
Max Fluid Temperature: 54°C (130°F)
Ambient Temperature: -10 to 43°C (14 to 110°F)
Max Viscosity: 1000 centipoise
Max Suction Lift: 3 m (10') water, 0 psig
Stroke Adjustment Range: 20:1, 5 to 100% stroke length
Cycle Time Adjustment Range (FPUD1100 Models Only): 20:1, 5 to 100% cycle time
Motor Speed Adjustment Range (FPUDM and FPUDVM Models Only): 20:1, 5 to 100%
Duty Cycle: Continuous
Enclosure: NEMA (IP21), FPUD1100 & FPUDM models; NEMA 3R (IP23), FPUDV and FPUDVM models; VALOX® thermoplastic
Wetted Materials: Polypropylene pump head, footvalve/strainer and check valve body/insert, PVDF cartridge valve body and tube adaptors, ceramic check balls; TFE/P and FKM O-rings; Hastelloy C-276 spring
Power: 115 Vac/60 Hz; 1.87 A max; 220 Vac/60 Hz, 220 or 240 Vac/50 Hz also available (special order only)
Connections: 38" OD suction and discharge tubing
Dimensions: 159 H x 235 W x 254 mm D (6.25 x 9.25 x 10")
Weight: 5.4 kg (12 lb) max PFUDV Digital Display Models Additional Specifications
External Speed Control: 4 to 20 mA, 0 to 10 Vdc, and pulse inputs
Display: LCD; indicate motor speed or input signal values, and service and alarm indicator icons
Dimensions: 159 H x 267 W x 254 mm D (6.25 x 10.5 x 10")
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
DIAPHRAGM FIXED SPEED
Mechanical Control
  
FPUDM1101
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 56.8 LPH (15.0 GPH)
  
FPUDM1102
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 48.2 LPH (12.7 GPH)
  
FPUDM1103
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 41.1 LPH (10.8 GPH)
  
FPUDM1104
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 24.6 LPH (6.4 GPH)
  
FPUDM1105
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 18.9 LPH (4.9 GPH)
  
FPUDM1106
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 14.4 LPH (3.8 GPH)
  
FPUDM1107
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 11.5 LPH (3 GPH)
  
FPUDM1108
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 9.1 LPH (2.4 GPH)
  
FPUDM1109
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 6 LPH (1.5 GPH)
Electronic Percentage
  
FPUD1101
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 56.8 LPH (15.0 GPH)
  
FPUD1102
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 48.2 LPH (12.7 GPH)
  
FPUD1103
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 41.1 LPH (10.8 GPH)
  
FPUD1104
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 24.6 LPH (6.4 GPH)
  
FPUD1105
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 18.9 LPH (4.9 GPH)
  
FPUD1106
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 14.4 LPH (3.8 GPH)
  
FPUD1107
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 11.5 LPH (3 GPH)
  
FPUD1108
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 9.1 LPH (2.4 GPH)
  
FPUD1109
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 6 LPH (1.5 GPH)
VARIABLE SPEED
Analog (No Signal Inputs)
  
FPUDVM1101
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 56.8 LPH (15.0 GPH)
  
FPUDVM1102
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 48.2 LPH (12.7 GPH)
  
FPUDVM1103
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 41.1 LPH (10.8 GPH)
  
FPUDVM1104
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 24.6 LPH (6.4 GPH)
  
FPUDVM1105
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 18.9 LPH (4.9 GPH)
  
FPUDVM1106
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 14.4 LPH (3.8 GPH)
  
FPUDVM1107
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 11.5 LPH (3 GPH)
  
FPUDVM1108
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 9.1 LPH (2.4 GPH)
  
FPUDVM1109
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 6 LPH (1.5 GPH)
Digital Touchpad (Accepts Signal Inputs)
  
FPUDV1101
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 56.8 LPH (15.0 GPH)
  
FPUDV1102
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 6 LPH (1.5 GPH)
  
FPUDV1103
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 41.1 LPH (10.8 GPH)
  
FPUDV1104
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 24.6 LPH (6.4 GPH)
  
FPUDV1105
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 18.9 LPH (4.9 GPH)
  
FPUDV1106
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 14.4 LPH (3.8 GPH)
  
FPUDV1107
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 11.5 LPH (3 GPH)
  
FPUDV1108
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 9.1 LPH (2.4 GPH)
  
FPUDV1109
Consult Sales  
Availability: 
 
 
Max. Feed Rate @ 0 PSI : 6 LPH (1.5 GPH)
Accessories
Click to expand/minimize a list of what others bought with theTYPE-3814-100
TYPE-3814-100
AUD105.34
Availability: 7 weeks
 
3/8 x 1/4" PE tubing, 30 m (100')
  
FPUD1000-V
Consult Sales  
Availability: 
 
 
Top and bottom valve assembly kit
  
FPUD1000-BC
Consult Sales  
Availability: 
 
 
Bullet cartridges (4-pack)
  
FPUD1000-D
Consult Sales  
Availability: 
 
 
Diaphragm PTFE/EP
  
FPUD1000-PHK
Consult Sales  
Availability: 
 
 
Complete pumphead kit (pumphead, top and bottom valves, diaphragm, and 4 mounting screws)
  
FPUSV-V
Consult Sales  
Availability: 
 
 
Foot valve strainer
  
FPU1000-AB
Consult Sales  
Availability: 
 
 
Armature bearings (life cycle, 5000 hours)
  
FPUD1000A-BK
Consult Sales  
Availability: 
 
 
Replacement brush kit for analog models
  
FPUD1000D-BK
Consult Sales  
Availability: 
 
 
Replacement brush kit for digital models
All amounts shown in AUD
Note: * Note: 260.8 GPD = 100 PSI max.; 305.7 GPD = 80 PSI max.; 360.0 GPD = 25 PSI max.

Comes complete with suction tube foot valve & strainer, suction tube weight, 1.5 m (5') PVC suction tubing, 3 m (10') PE discharge tubing and injection fitting with internal back-flow check valve, mounting hardware and operator’s manual.


Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Variable Speed select from:
Nothing(leave field blank) for None
V for Variable speed digital touchpad
VM for Variable speed dial knob control

(2) Motor Speed Adjustment select from:
Nothing(leave field blank) for None
M for Motor speed adjustment

(3) Max Feed Rate select from:
01 for 15.0 GPH (56.8 LPH)
02 for 12.7 GPH (48.2 LPH)
03 for 10.8 GPH (41.1 LPH)
04 for 6.4 GPH (24.6 LPH)
05 for 4.9 GPH (18.9 LPH)
06 for 3.8 GPH (14.4 LPH)
07 for 3.0 GPH (11.5 LPH)
08 for 2.4 GPH (9.1 LPH)
09 for 1.5 GPH (6.0 LPH)
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.