HHC200 Series Rugged Environmental Monitors
The HHC200 Series of Handheld Monitors are designed to cover most environmental field monitoring needs. They are ruggedize with a built in bumper band and have a unique metal slide on cover to protect them when not in use, or in a tool box or on a truck seat. The units are also compact to easily fit in tool belts or tool kits measuring just 1” x 2” x 5.25”.
TEMPERATURE
The HHC201 is a dual input thermocouple thermometers with 0.1% accuracy, auto ranging 0.1 degree or 1 degree resolution, and provided with 2 type K thermocouples. Its measurement range is -76 to 2500°F or -100 to 1372°C. The backlit triple display shows T1, T2 and T1-T2. Hold, Min, Max, Max-Min and Average temperature are also selectable.
The HHC210 is an Infrared thermometer with laser spot sighting and a 6:1 field of view. Emissivity is adjustable from 0.1 to 1.00. Its measurement range is -22 to 1022°F or -30 to 550°C with accuracy of ±2°C below 100°C and ±2% reading over 100°C. It will operate in an ambient of –4 to 140°F. The backlit display shows Infrared temperature, ambient temperature and the difference between the two. Hold, Min, Max, Max-Min and Average temperature are also selectable.
PRESSURE
The HHC280 is low pressure manometer measuring gage or differential pressures from 0 to 40 inH2O
(1.45 psi). Working media is clean dry non-conductive gases. The backlit display shows P1 gage pressure and P1-P2 differential pressure. The pressure can be displayed in 8 different engineering units and is compliant with pitot tubes for measuring air velocity. Hold, Min, Max, Max-Min and Average temperature are also selectable.
The HHC281 measures absolute pressure (zero reference is abaolute zero). It has eight enginnering units plus meters and feet for altitude measurement. The absolute pressure range is 4.35 psia to 17.3 psia.
The backlit display will display either pressure or altitude. Hold, Min, Max, Max-Min and Average temperature are also selectable.
Air Flow/Humidity/Dew Point/Wet Bulb/Wind Chill
The HHC261 is a precision Hygro-Anemometer for measuring outdoor or laboratory created conditions. It measures air flow to 4000 ft/min velocity, air temperature, and humidity and computes Dew Point, wet bulb, and Wind Chill values. Hold, Min, Max, Max-Min and Average temperature are also selectable.
LIGHT
The HHC230 is an environmental light meter, measuring the illumination in either lux or ft-candles.
The illumination is used to setup lighting for various workstations to optimize efficiencies.
A table is provided: examples: General office 1500 to 2000 lux, Meeting room 300 to 700 lux. Hold, Min, Max, Max-Min and Average temperature are also selectable.
Non-Contact RPM
The HHC250 is a non-contact RMP meter, measuring rotation up to 99,999 rpm. At slower speeds the meter autoranges to rps with 0.1 resolution. For non-contact measurements. a small piece of reflective tape is added to the rotating device. The meter has a red LED to mark the spot where it is viewing to assure accurate readings. Hold, Min, Max, Max-Min and Average temperature are also selectable.
Featured here the HHC200 Series of digital portable thermometers is a great option for temperature measurement in environmental applications. It is offered in two different models: infrared thermometer and dual thermocouple thermometer.
Dual Thermocouple Thermometer - HHC201
Specifications Units: °C or °F Range: -200 to 1372°C (-328 to 2500°F) Resolution: 0.1°: -100 to 1372°C (-148 to 2500°F) 1°: -200 to -100°C (-328 to -148°F) Accuracy: Type K thermocouple ITS-90 ±(0.1% rdg +1°C): -60 to 1372°C (-76 to 2500°F) ±(0.1% rdg +2°C): -200 to -60°C (-328 to -76°F) Operating Temperature: 0 to 50°C (32 to 122°F) Power: 2 “AAA” batteries (included) Battery Life: 250 hours typical with alkaline batteries Dimensions: 24.7 x 50.9 x 132.9 mm (0.98 x 2.0 x 5.2") Weight: 148 g (5.2 oz)
Comes complete with batteries, carrying strap, protection cap, and thermocouple.
Portable Infrared Thermometer - HHC210
Specifications Units: °C or °F Infrared Temperature: FOV: 100 mm (4") @ 600 mm (24") Range: -30 to 550°C (-22 to 1022°F) Resolution: 0.1° Accuracy: ±2°C: -30 to 100°C (-22 to 212°F) ±2% rdg: 101 to 550°C (214 to 1022°F) Air Temperature: Range: -20 to 60°C (-4 to 140°F) Accuracy: ±0.5°C: 0 to 45°C (32 to 116°F) ±1°C: -20 to 0°C (-4 to 32°F); 45 to 60°C (116 to 140°F) Operating Temperature: 0 to 50°C (32 to 122°F) Power: 2 “AAA” batteries (included) Battery Life: 40 hour with laser typical with alkaline batteries Dimensions: 24.7 x 50.9 x 132.9 mm (0.98 x 2.0 x 5.2") Weight: 148 g (5.2 oz)
Comes complete with batteries, carrying strap, and protection cap.
† All amounts shown in AUD Note: Comes with a slip on protective cover. Ordering Example: (1) HHC201 Handheld Thermometer, 2 Type K inputs, AUD209.61