The LCM402 and LCM412 are also available in standard configurations, with 0-50 to 0-750,000 lb ranges and standard threads.
Please see the LC402 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS Excitation: 10 Vdc (15 Vdc max) Output: 3 mV/V ±0.25% 5-Point Calibration: 0%, 50%, 100%, 50%, 0% in compression Linearity: 0.10% FSO Hysteresis: 0.10% FSO Repeatability: 0.05% FSO Zero Balance: ±1% FSO Operating Temp Range: LC402: -54 to 107°C (-65 to 225°F) LC412: -54 to 127°C (-65 to 260°F) Compensated Temp Range: 16 to 71°C (60 to 160°F) Thermal Effects: Zero: 0.0025% FSO/°F Span: 0.0025% FSO/°F Safe Overload: 150% of Capacity Ultimate Overload: ranges ≤400,000 lb: 300% of Capacity ranges >400,000 lb: 200% of Capacity Bridge Resistance: 350 ±10 Ω FS Deflection: 0.025 to 0.075 mm (0.001 to .003") typical Construction: 17-4 PH Stainless Steel Electrical Connection: LC402/LCM402: 15 ft (4.8 m) 4-conductor shielded PVC cable LC412/LCM412: DT02H-10-6P connect (or equivalent) Mating Connector: PT06F10-6S, sold separately
† All amounts shown in AUD Note: Comes with 5-point calibration at 0%, 50%, 100%, 50%, 0% of full scale in compression. Units ordered with optional tension plate calibrated in tension. Ordering Example: (1) PT06F10-6S mating connector, AUD65.77