Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

FLOAT LEVEL TRANSMITTER

LVR500 Series

Float Level Transmitter
 | LVR500 Series

Float Level Transmitter

CE
  • Level Measurement Up to 2 m (6.5') for High Pressure or Temperature applications
  • Rugged 316 Stainless Steel Float Guide and Process Mounting Plug
  • Polypropylene Junction Box Rated NEMA 4X (IP65) with Conduit Port and Terminal Strip
  • Great for High Pressure Applications Up to 200 psi (13.8 bar)
  • Use in Applications with Foam or Turbulence
  • Loop Powered Output Interfaces Directly with PLC/SCADA or Local Display
Level Switches & Transmitters - View related products

Description

The LVR500 Series float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels.

Specifications
Range: 41 to 1222 cm (16 to 48")
Accuracy: 0.25% span in water
Configuration: None, fixed span
Orientation: ±20° from vertical
Specific Gravity: 0.55 min
Supply Voltage: 10 to 30 Vdc
Loop Resistance: 600 Ω @ 24 Vdc
Signal Output: 4 to 20 mA, two-wire
Process Temp: -40 to 85°C (-40 to 185°F)
Ambient Temp: -40 to 60°C (-40 to 140°F)
Pressure: 200 psi (13.8 bar)
Enclosure Rating: NEMA 4X (IP65)
Enclosure Material: PP
Conduit Entrance: Single, 1/2 NPT
Process Mount: 2 NPT
Guide-Float Material: 316 SS
Classification: General purpose
Compliance: CE
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
LVR516
AUD2,005.00
Availability: 1 week
 
Level transmitter, 4 to 20 mA output, range 41 cm (16")
LVR524
AUD2,418.17
Availability: 1 week
 
Level transmitter, 4 to 20 mA output, range 61 cm (24")
LVR532
AUD2,865.00
Availability: 15 weeks
 
Level transmitter, 4 to 20 mA output, range 81 cm (32")
LVR536
AUD3,035.00
Availability: 15 weeks
 
Level transmitter, 4 to 20 mA output, range 91cm (36")
LVR542
AUD3,365.00
Availability: 15 weeks
 
Level transmitter, 4 to 20 mA output, range 107 cm (42")
LVR548
AUD3,670.00
Availability: 15 weeks
 
Level transmitter, 4 to 20 mA output, range 122 cm (48")
All amounts shown in AUD
Note: Comes complete with operator’s manual.


We noticed you are from the US. Visit your local site for regional offers and live support.