Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

M12 Stainless Steel RTD Temperature Transmitters

M12TXSS

M12 Stainless Steel RTD Temperature Transmitters | M12TXSS

M12 Stainless Steel RTD Temperature Transmitters

CE
  • Programmable Transmitter
  • M12 Connection
  • 4 to 20 mA Output = 0 to 100°C Default Setting
  • -50 to 120°C (-58 to 248°F) Full Programmable Range
  • Statinless Steel (IP67)
RTD (PT100)  Probes, Elements and Assemblies - View related products

Description

RTD 100 Ω sensor with built-in transmitter is programmable by a computer. The configuration kit required for programming is M12TX-CONFIG. This unique probe is ideal for areas with space limitations where traditional head connections are too large to fit. The M12 thread design offers a secure industrial connection.

Specifications
Body: Stainless steel AISI 316L
Probe Length: 13 mm (0.51") and 24 mm (0.94")
Diameter: Ø 3 mm (0.1")
Probe Type: Thermowell AISI 316L SS
Probe Minimum Bending Radius: Three-times the outer diameter [except the sensing tip which length is 30 mm (1.2")]
Connection: 1/8 NPT male thread
Sensor: RTD PT100 class A up to 300°C in accordance to IEC751
Range: -50 to 120°C (-58 to 248°F)
Tmax. Electronic: 80°C (176°F)
Sensor Break Monitoring:
    Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action
    Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
Output:
    Signal: 4 to 20 mA
    Permissible Load: 700 @ 24 Vdc [RLo= (Vsupply-8,5)/0,020]
Default Factory Setting for 4 to 20mA output: 0 to 100°C
Response Time (90%): <50 ms
Isolation In-Out: Non-isolated
Power Supply: 8.5 to 32 Vdc (polarity protected)
Environment Conditions:
    Temperature: -40 to 80°C (-40 to 176°F) for plastic body
    Relative Humidity: 0 to 100%
    EMC: In accordance to EN 61326
    Degree of Protection: IP65 and IP67 in accordance to IEC60529
Accuracy:
    Transmitter: Maximum of ±0.2°C or ±0.2% of span
    Sensor: Class A in accordance to IEC751
Temperature Influence [Deviation from 20°C (68°F)]: Maximum of ±0.3°C/25°C (77°F) or ±0.3% of span/25°C (77°F)
Supply Voltage Influence: Negligible
Range Configurations: It is possible set the input temperature range (span) by the M12TX-CONFIG configuration kit (PC with OS Windows required)
Zero Adjustments: Any value between -50 to 50°C
Minimum Span: 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
Sensor Error Compensation: Over 2 points (maximum 1% of span)
Factory Setting: 0 to 100°C/sensor break >21 mA (upscale)
Response Time: Diameter 3 mm <3.5 seconds, diameter 6 mm <13 seconds (test in water to IEC751- time for reaching 63.2% of instantaneous temperature change)
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
Standard
Click to expand/minimize a list of what others bought with theM12TXSS-PT100-13MM-1/8NPT
M12TXSS-PT100-13MM-1/8NPT
AUD234.25
Availability: 3 weeks
 
Temperature transmitter with M12 input connector for Pt100, output 4 to 20 mA standard, 3 mm (0.118') diameter, 13 mm (0.51') long, 1⁄8 NPT
Click to expand/minimize a list of what others bought with theM12TXSS-PT100-24MM-1/8NPT
M12TXSS-PT100-24MM-1/8NPT
AUD241.42
Availability: 2 weeks
 
temperature transmitter with M12 input connector for Pt100, output 4 to 20 mA standard, 3 mm (0.118') diameter, 24 mm (0.94') long, 1⁄8 NPT
Metric
  
M12TXSS-PT100-13MM-G1/8
AUD234.00
Availability: 13 weeks
 
Temperature transmitter with M12 input connector for Pt100, output 4 to 20 mA standard, 3 mm (0.118') diameter, 13 mm (0.51') long, G1⁄8 Thread
  
M12TXSS-PT100-24MM-G1/8
AUD228.00
Availability: 2 weeks
 
temperature transmitter with M12 input connector for Pt100, output 4 to 20 mA standard, 3 mm (0.118') diameter, 24 mm (0.94') long, G1⁄8 Thread
Accessories
  
M12TX-CONFIG
Consult Sales  
Availability: 
 
 
Configuration kit for M12TXSS, USB serial interface, connection cables, programming software for Windows®
  
M12CFM-P24STPC-SFSR-FL-3
AUD89.00
Availability: 1 week
 
PVC insulated and jacketed 24 AWG stranded with M12 straight socket and 3 meters length cable
  
M12CFM-P24STPC-SFSR-FL-20
AUD149.00
Availability: 6 weeks
 
PVC insulated and jacketed 24 AWG stranded with M12 straight socket and 20 meters length cable
  
M12TX-CONFIG-SET
AUD635.00
Availability: 3 weeks
 
Accessory to configure the M12TX series devices through a PC with Windows 10 or higher and the TTX-Platform software
All amounts shown in AUD
Note: Comes complete with operator’s manual.
Ordering Example:  (1) M12TXSS-PT100-13MM-1/8NPT Temperature transmitter with M12 input connector for Pt100, output 4 to 20 mA standard, 3 mm (0.118'') diameter, 13 mm (0.51'') long, 1/8 NPT, AUD234.25

Product Manuals:

Download M12 Series - Temperature Transmitter with 100 Ohm RTD
Download M12TX-CONFIG - Configuration Kit for M12TX
We noticed you are from the US. Visit your local site for regional offers and live support.