High Accuracy Pressure Standards, Microprocessor-Based Dual Display, Digital and Analog

PCL-3000

High Accuracy Pressure Standards, Microprocessor-Based Dual Display, Digital and Analog | PCL-3000

  • Switch Selectable Ranges - Absolute or Gage
  • Accuracy ±0.05% FS,
  • Ranges - From 10 to 10,000 psi
  • Automatic Zeroing (No Potentiometer Needed)
  • Self-Calibrating
  • Digital Output RS-232 Optional
  • Integral Stainless Steel Transducer
  • 2-Year Warranty
Instrumentation for Pressure and Strain Measurements - View related products

Description

PCL-3000 Series digital pressure standards are specifically designed for use in the manufacture, testing, or calibration of pressure-sensitive devices. Using a patented, bonded foil strain-gage sensor and advanced microcircuitry, these rugged, compact instruments provide simultaneous digital and analog readouts of the pressures applied. Standard front panel switches permit desired pressure range selection, automatic zeroing of the display and actuation of a unique internal self-calibration feature. Each instrument has two displays, digital and analog. The digital display provides precise pressure information and the analog display gives a quick reference to direction and level of pressure.

SPECIFICATIONS
Accuracy: ±0.05% FS max., each range. (Accuracy statement includes linearity, hysteresis and repeatability.)
Operating Temperature: 10 to 43°C (50 to 110°F)
Pressure Media: Any media compatible with 17-4 PH Stainless Steel
Overpressure Capability: 750% FS on lowest range; 300% FS on mid. range; 150% FS on highest range
Display Resolution: Nominally 0.02% FS for each pressure range
Reading Rate: 10/sec
Input Voltage: 117 or 220 Vac ±10%, 50/60 Hz Voltage selected via transformer taps
Pressure Connection: 7/16-20 UNFM
Power Consumption: 8 watts, typical
Nominal Size: 27 W x 12 Hx 25 cm D (10.8 W x 4.9 H x 9.9" D)
Panel Cutout: 26.9 x 12 cm (10.62 x 4.75")
Weight: 2.3 kg (5 lb)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
PCL-3000A
Consult Sales  
Availability: 
 
 
Pressure standard with 0-5,000, 0-2,500 and 0-1,000 psia or psig selectable ranges
PCL-3000B
Consult Sales  
Availability: 
 
 
Pressure standard with 0-1,000, 0-500 and 0-200 psia or psig selectable ranges
PCL-3000C
Consult Sales  
Availability: 
 
 
Pressure standard with 0-500, 0-250 and 0-100 psia or psig selectable ranges
PCL-3000D
Consult Sales  
Availability: 
 
 
Pressure standard with 0-100, 0-50 and 0-20 psig selectable ranges with conversion to Inches of Water
PCL-3000E
Consult Sales  
Availability: 
 
 
Pressure standard with 0-50, 0-25 and 0-10 psig selectable ranges with conversion to Inches of Water
PCL-3000G
Consult Sales  
Availability: 
 
 
Pressure standard with 0-10,000, 0-5,000 and 0-2,000 psia or psig selectable ranges
All amounts shown in AUD
Note: All models come with an NIST traceable calibration certificate.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Ranges select from:
A for 5000/2500/1000 psig and psia
B for 1000/500/200 psig and psia
C for 500/250/100 psig and psia
D for 100/50/20 psig with conversion to InH2O
E for 50/25/10 psig with conversion to inH2O
G for 10000/5000/2000 psig and psia

(2) Options select from:
for no options leave blank
-1 for Isolated analog output (0-10vdc or 4-20 ma)
-4 for RS232 simplex output
-5 for Peak hold
-7 for Battery option (excludes bargraph display)
-9 for Panel mounting kit
-10 for Freeze mode for testing pressure switches
Note: All combinations may not be valid, check spec sheet for valid part numbers.