  • For Dry Gases
  • Ranges from 0.25 inH2 O to 100 inH2 O
  • For Use in Building Management, HVAC Ducts or Clean Rooms
  • Works with Unregulated Voltage Source
  • Fully Protected Against Incorrect Wiring
Pressure Transducers - View related products

Description

SPECIFICATIONS
Excitation: 9 to 30 Vdc unregulated
Output Impedance: <100Ω
Output Span: Set to 5 Vdc ±50 mV
Zero Offset: Set to ±50 mV
Accuracy: ±1% BFSL at constant temperature (includes linearity, repeatability and hysteresis)
Linearity: ±0.98% FS (typical)
Hysteresis: 0.1% FS (typical)
Repeatability: ±0.05% FS Compensated Temperature Range: -18 to 65°C (0 to 149°F)
Thermal Effects: ±0.06%/°C (#177;0.033%/°F)
Proof Pressure: ±10 psi, all ranges
Position Effect: Factory calibration with diaphragm vertical
RangeZero Offset (%FS/G)
0 to 0.5 in H2O0.6
0 to 1 in H2O2.2
0 to 5 in H2O1.4

Sensor: Capacitive
Media: Air or similar non-conducting gases
Pressure Port: 3/16" OD pressure fitting for 1/4" tube
Case: Fire-retardant glass-filled polyester
Mounting: 2 tabs with #8 holes
Electrical Connection: Screw terminals
Weight: 85 g (3 oz)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
Unidirectional Ranges
PX2650-0.5D5V
AUD510.00
Availability: 1 week
 
0 to 0.5 inH2O Differential Transducer
PX2650-2D5V
AUD485.00
Availability: 9 weeks
 
0 to 2 inH2O Differential Transducer
PX2650-10D5V
AUD485.00
Availability: 9 weeks
 
0 to 10 inH2O Differential Transducer
PX2650-25D5V
AUD510.00
Availability: 5 weeks
 
0 to 25 inH2O Differential Transducer
PX2650-50D5V
AUD485.00
Availability: 5 weeks
 
0 to 50 inH2O Differential Transducer
PX2650-100D5V
AUD515.00
Availability: 5 weeks
 
0 to 100 inH2O Differential Transducer
Bidirectional Ranges
PX2650-0.25BD5V
AUD515.00
Availability: 1 week
 
±0.25 inH2O Differential Transducer
PX2650-1BD5V
AUD515.00
Availability: 5 weeks
 
±1 inH2O Differential Transducer
PX2650-2BD5V
AUD510.00
Availability: 4 weeks
 
±2 inH2O Differential Transducer
PX2650-5BD5V
AUD515.00
Availability: 5 weeks
 
±5 inH2O Differential Transducer
PX2650-10BD5V
AUD515.00
Availability: 5 weeks
 
±10 inH2O Differential Transducer
PX2650-25BD5V
AUD515.00
Availability: 4 weeks
 
±25 inH2O Differential Transducer
PX2650-50BD5V
AUD505.00
Availability: 5 weeks
 
±50 inH2O Differential Transducer
All amounts shown in AUD
Note: All models come with complete operator’s manual.