Cart  |  Contact  |  Help  |  auinfo@dwyeromega.com  | 
Toll-Free in Australia: 1800 106 210
International+65 6415 5353

RTD Bullet Probes

RTD Bullet Probes

RTD Bullet Probes | RTD Bullet Probes

RTD Bullet Probes

AUD69.00 A/100-2W-BP-20-CL2P

  • Monitor air temperatures
  • 1” stainless probe
  • Manufactured to eliminate the effects of moisture
  • Fast response time
RTD (PT100)  Probes, Elements and Assemblies - View related products

Description

The ACI Platinum Bullet Probe Series feature a one inch stainless steel probe and are manufactured using ACI’s proven double encapsulation process to eliminate the effects of moisture upon the sensors and to increase the response time using high quality, thermally conductive epoxy. The bullet style sensor is designed to be used to monitor air temperatures and should not be fully submerged in water.

Applications: Roof Top Units, Air Handlers, Discharge Air/Supply/Return/Mixed Air Duct Temperature, Remote Temperature Sensing, Hydronic Systems

Sensor Type | Sensor Curve: Platinum RTD | PTC (Positive Temperature Coefficient)
Number Sensing Points: One
Number Wires: A/100-2W-BP Series and A/1K-2W-BP Series: Two (Non-Polarity Sensitive)
A/100-3W-BP Series and A/1K-3W-BP Series: Three (Polarity Sensitive)
Sensor Output @ 0°C (32°F): A/100-xW-BP Series: 100 Ohms nominal | A/1K-xW-BP Series: 1000 Ohms nominal
Platinum RTD Tolerance Class: +/- 0.06% Class A (Tolerance Formula: +/- 0°C = (0.15°C + (0.002 * |t|))
-40°C (-40°F): +/- 0.23°C (+/- 0.414°F) | 0°C (32°F): +/- 0.15°C (+/- 0.27°F)
200°C (392°F): +/- 0.55°C (+/- 0.99°F)
Platinum RTD Din Standard: DIN EN 60751 (IEC 751) | 3850 ppm / °C
Platinum RTD Stability: +/- 0.03% after 1000 Hours @ 300°C (572°F)
Platinum RTD Response Time (63% Step Change): 8 Seconds nominal
Self-Heating | Maximum Operating Current: 100 Ohm RTD: 7 mW/°C (Still Air) | 5 mA
1K Ohm RTD: 4mW/°C (Still Air) | 3 mA
Operating Temperature Range: -40 to 200°C (-40 to 392°F)
Storage Temperature Range: -40 to 85°C (-40 to 185°F)
Operating RH Range: 10 to 95% RH, non-condensing
Conductor Material: Silver Plated Copper
Probe Material: 304 Stainless Steel
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
A/100-3W-BP-10-CL2P
AUD52.00
Availability: 2 weeks
 
100 Ohm (Two Wires) RTD, Bullet Probe, 1", 10' Plenum Cable
A/1K-3W-BP-10-CL2P
AUD52.00
Availability: 2 weeks
 
1,000 Ohm (Three Wires) RTD, Bullet Probe, 1", 10' Plenum Cable
A/100-2W-BP-20-CL2P
AUD69.00
Availability: 2 weeks
 
100 Ohm (Two Wires) RTD, Bullet Probe, 1", 20' Plenum Cable
A/100-3W-BP-20-CL2P
AUD69.00
Availability: 2 weeks
 
100 Ohm (Three Wires) RTD, Bullet Probe, 1", 20' Plenum Cable
A/1K-2W-BP-20-CL2P
AUD69.00
Availability: 2 weeks
 
1,000 Ohm (Two Wires) RTD, Bullet Probe, 1", 20' Plenum Cable
A/1K-3W-BP-20-CL2P
AUD69.00
Availability: 2 weeks
 
1,000 Ohm (Three Wires) RTD, Bullet Probe, 1", 20' Plenum Cable
All amounts shown in AUD
We noticed you are from the US. Visit your local site for regional offers and live support.