AUD21.00 A/20K-R2
Description
The ACI Thermistor Room Series combines option flexibility with attractive styling in the R2 style enclosure which includes four-way air flow design to minimize self-heating to the sensor. These units are designed to be mounted over a single gang junction box or hole in the wall using drywall anchors. Screw terminal blocks are available for making all
connections to your building management system (network).
Applications: Space Temperature Sensing, Decorative Wall Sensor Applications, Office Buildings, Schools, Colleges, Commercial Buildings, OEM Opportunities
For more information Please visit www.workaci.com
Sensor Type: | Thermistor |
Sensor Curve: | Non-Linear, NTC (Negative Temperature Coefficient) |
Accuracy 0-70ºC (32-158ºF): | +/- 0.2°C (+/-0.36°F) A/10K-E1 Series: +/-0.3°C (+/-0.54°F) A/1.8K Series: +/-0.5°C @ 25°C (77°F) and +/-1.0°C (+/-1.8°F) |
Stability: | Sensor Dependent; Contact ACI for more information on specific sensor |
Response Time (63% Step Change): | 10 Seconds nominal |
Power Dissipation Constant: | 3 mW/°C A/1.8K Series: 1 mW/°C A/10K-E1 Series: 2 mW/°C |
LCD Display Supply Voltage: | +9 to 35 VDC / 24 VAC (50-60 Hz) < 4 mA / 0.12 VA |
LCD Display Accuracy: | +/- 2°F or +/- 2°C @ 71°F (21.5°C) Typical |
LCD Display Descriptor | Number of Digits: | °F (Fahrenheit) or °C (Celsius) | 3 1/2 Segment Display |
LCD Display Life Expectancy: | 50,000 Hours Minimum |
Set Point Tolerance: | +/- 10% of Range |
Override Option: | Short Thermistor (Default); Field (Jumper) Selectable “Dry Contact” Closure (Separate Input); Short Set Point available upon request |
Operating Temperature Range: | 1.5 to 50°C (35 to 122°F) |
Storage Temperature Range: | Non-LCD: -40 to 65°C (-40 to 149°F) LCD Display: -10 to 65°C (14 to 149°F) |
Operating Humidity Range: | 10 to 95%RH, non-condensing |
Connections | Wire Size: | Screw Terminal Blocks | 16 (1.31 mm) to 26 (0.129 mm) AWG |
Terminal Block Torque Rating: | 0.5 Nm (minimum); 0.6 Nm (maximum) |
Enclosure Material | Color: | “-R2” Enclosure: ABS Plastic | White, UL94-HB “R” Enclosure: ABS Plastic | Beige UL94-HB |
Sensor Type: | Thermistor |
Sensor Curve: | Non-Linear, NTC (Negative Temperature Coefficient) |
Accuracy 0-70ºC (32-158ºF): | +/- 0.2°C (+/-0.36°F) |
Stability: | Sensor Dependent; Contact ACI for more information on specific sensor |
Response Time (63% Step Change): | 10 Seconds nominal |
Power Dissipation Constant: | 3 mW/°C |
LCD Display Supply Voltage: | +9 to 35 VDC / 24 VAC (50-60 Hz) |
LCD Display Current: | < 4 mA / 0.12 VA |
LCD Display Accuracy: | +/- 2°F or +/- 2°C @ 71°F (21.5°C) Typical |
LCD Display Descriptor | Number of Digits: | °F (Fahrenheit) or °C (Celsius) | 3 1/2 Segment Display |
LCD Display Life Expectancy: | 50,000 Hours Minimum |
Set Point Tolerance: | +/- 10% of Range |
Override Option: | Short Thermistor (Default); Field (Jumper) Selectable “Dry Contact” Closure (Separate Input); Short Set Point available upon request |
Operating Temperature Range: | 1.5 to 50°C (35 to 122°F) |
Storage Temperature Range: | Non-LCD: -40 to 65°C (-40 to 149°F) LCD Display: -10 to 65°C (14 to 149°F) |
Operating Humidity Range: | 10 to 95%RH, non-condensing |
Connections | Wire Size: | Screw Terminal Blocks | 16 (1.31 mm) to 26 (0.129 mm) AWG |
Terminal Block Torque Rating: | 0.5 Nm (minimum); 0.6 Nm (maximum) |
Enclosure Material | Color: | “-R2” Enclosure: ABS Plastic | White, UL94-HB “R” Enclosure: ABS Plastic | Beige UL94-HB |