Rugged Transition Joint Probe Rigid BX Armor Cable over Lead Wire with Std Size Male Connector

TJ36-BX Series

Rugged Thermocouple Probes | TJ36-BX Series

Rugged Thermocouple Probes

AUD164.37 TJ36-CAIN-14U-12-BX-OSTW-M

  • Rigid SS BX Armor Cable Offers Splash Protection from Tools, Solder, Molten Plastics, etc.
  • Manufactured with OMEGACLAD™ Compacted Mineral Insulated Cable for Long-Lasting, Low-Drift Performance in Harsh Conditions
  • 1 m (40") Lead Length Standard
  • 304 SS and Inconel® 600 sheaths. Also available with Super Omegaclad® XL Sheath!
  • Standard Male Connector has OMEGA's Write-On Window Feature
Thermocouples - View related products

Description

Matching Super OMEGACLAD™ XL mineral insulated thermocouple cable with our rugged transition joint probes and BX armored cable makes a combination that's hard to beat! Perfect for quick readings at higher temperatures or monitoring elevated temperatures for extended periods of time.

Calibration
ANSI Code
Sheath
Materials
Sheath Dia.
mm (in.)
T/C Junction
Upper Temp.
°C (°F)
Model Number
(See notes, below)
K
CHR-
AL
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
899 (1650)
899 (1650)
899 (1650)
899 (1650)
TJ36-CASS-116(*)-(**)-BX-OSTW-M
TJ36-CASS-18(*)-(**)-BX-OSTW-M
TJ36-CASS-316(*)-(**)-BX-OSTW-M
TJ36-CASS-14(*)-(**)-BX-OSTW-M
Inconel®
600
1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
921 (1690)
1071 (1960)
1149 (2100)
1149 (2100)
TJ36-CAIN-116(*)-(**)-BX-OSTW-M
TJ36-CAIN-18(*)-(**)-BX-OSTW-M
TJ36-CAIN-316(*)-(**)-BX-OSTW-M
TJ36-CAIN-14(*)-(**)-BX-OSTW-M
Super
OMEGACLAD™
XL
1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
1038 (1900)
1149 (2100)
1204 (2200)
1204 (2200)
TJ36-CAXL-116(*)-(**)-BX-OSTW-M
TJ36-CAXL-18(*)-(**)-BX-OSTW-M
TJ36-CAXL-316(*)-(**)-BX-OSTW-M
TJ36-CAXL-14(*)-(**)-BX-OSTW-M
J
Iron-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
441 (825)
521 (970)
621 (1150)
721 (1330)
TJ36-ICSS-116(*)-(**)-BX-OSTW-M
TJ36-ICSS-18(*)-(**)-BX-OSTW-M
TJ36-ICSS-316(*)-(**)-BX-OSTW-M
TJ36-ICSS-14(*)-(**)-BX-OSTW-M
T
Copper-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
260 (500)
316 (600)
371 (700)
371 (700)
TJ36-CPSS-116(*)-(**)-BX-OSTW-M
TJ36-CPSS-18(*)-(**)-BX-OSTW-M
TJ36-CPSS-316(*)-(**)-BX-OSTW-M
TJ36-CPSS-14(*)-(**)-BX-OSTW-M
Notes: *Specify Junction: (G)rounded, (E)xposed or or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NN for CA in Model Number.

View the Thermocouple Accuracy and Color Code charts
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
TJ36-CAIN-18U-12-BX-OSTW-M
AUD138.00
Availability: 7 weeks
 
Rugged Transition Joint Probe with Inconel® sheath and BX armor over PFA lead wire, Type K calibration, 1/8 in. (3 mm) sheath dia., ungrounded tip, 12 in. (300 mm) sheath length, and 1 m (40 in. PFA lead wire).
TJ36-ICSS-316E-12-BX-OSTW-M
AUD134.00
Availability: 7 weeks
 
Rugged Transition Joint Probe with 304 SS sheath and BX armor over PFA lead wire, Type J calibration, 3/16 in. (4.5 mm) sheath dia., ungrounded tip, 12 in. (300 mm) sheath length, and 1 m (40 in. PFA lead wire).
TJ36-CPSS-116G-12-BX-OSTW-M
AUD134.00
Availability: 7 weeks
 
Rugged Transition Joint Probe with 304 SS sheath and BX armor over PFA lead wire, Type T calibration, 1/16 in. (1.5 mm) sheath dia., grounded tip, 12 in. (300 mm) sheath length, and 1 m (40 in. PFA lead wire).
TJ36-CAXL-14U-6-BX-OSTW-M
AUD169.00
Availability: 7 weeks
 
Rugged Transition Joint Probe with Super OMEGACLAD™ XL sheath and BX armor over PFA lead wire, Type K calibration, 1/4 in. (6 mm) sheath dia., ungrounded tip, 6 in. (150 mm) sheath length, and 1 m (40 in. PFA lead wire).
TJ36-CASS-14G-18-BX-OSTW-M
AUD161.00
Availability: 7 weeks
 
Rugged Transition Joint Probe with 304 SS sheath and BX armor over PFA lead wire, Type K calibration, 1/4 in. (6 mm) sheath dia., grounded tip, 18 in. (450 mm) sheath length, and 1 m (40 in. PFA lead wire).
All amounts shown in AUD
Note: Additional lead wire is priced at $2.25 per ft (300 mm) for all models. Contact Sales for prices on additional probe lengths.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) TJ36-CAXL-14U-12-BX-OSTW-M TJ36 rugged transition joint probe with BX armor cable over PFA lead wire and Super OMEGACLAD™ XL sheathed probe. The 1/4 in. dia. probe has an ungrounded tip and is 12 inches (300 mm) long., AUD172.00

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Calibration select from:
CA for Type K
IC for Type J
CP for Type T
NN for Type N

(2) Sheath Material select from:
SS for 304 Stainless Steel
IN for Inconel® 600
XL for Super OMEGACLAD™ XL

(3) Probe Diameter select from:
116 for 1/16 in. (1.5 mm)
18 for 1/8 in. (3 mm)
316 for 3/16 in. (4.5 mm)
14 for 1/4 in. (6 mm)

(4) Junction Type select from:
E for Exposed Tip
G for Grounded Tip
U for Ungrounded Tip

(5) Probe Length select from:
6 for 6 in. (150 mm)
12 for 12 in. (300 mm)
18 for 18 in. (450 mm)
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.