Rugged Thermocouple Transition Joint Probe with Stainless Steel Braid over PFA Lead Wire and Miniature Male Connector/Cable Clamp

TJ36-SB Series

Rugged Thermocouple Transition Joint Probe with Stainless Steel Braid over PFA Lead Wire and Miniature Male Connector/Cable Clamp | TJ36-SB Series

AUD134.48 TJ36-CASS-18U-6-SB-SMPW-M

  • Stainless Steel Overbraid Resists Abrasions and Cuts, yet Remains Flexible
  • 1 m (40 in.) Lead Length
  • 304 SS and Inconel® 600 sheaths. Also available with Super Omegaclad® XL sheath!
  • Manufactured with OMEGACLAD™ Compacted Mineral Insulation Cable for Long-Lasting, Low-Drift Performance in Harsh Conditions!
  • Lead Wire Rated to 260°C (500°F)
  • Spring Strain Relief Prevents "Pinching" of the Wire
  • Miniature Male Connector Features OMEGA's Write-On Window and Cable Clamp
Sensors - View related products

Description

For long life, drift-free operation, choose Super OMEGACLAD™ XL mineral insulated thermocouple cable and our rugged transition joint probes, which are available in Type K and N calibrations. PFA lead wire with a stainless steel overbraid resists abrasions and provides a cost-effective solution for environmental temperatures to 260°C (500°F). See the highlighted section in the table.

Calibration
ANSI Code
Sheath
Materials
Sheath Dia.
mm (in.)
T/C Junction
Upper Temp.
°C (°F)
Model Number
(See notes, below)
K
Chromega® -
AL
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
899 (1650)
899 (1650)
899 (1650)
899 (1650)
TJ36-CASS-116(*)-(**)-SB-SMPW-M
TJ36-CASS-18(*)-(**)-SB-SMPW-M
TJ36-CASS-316(*)-(**)-SB-SMPW-M
TJ36-CASS-14(*)-(**)-SB-SMPW-M
INC600 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
921 (1690)
1071 (1960)
1149 (2100)
1149 (2100)
TJ36-CAIN-116(*)-(**)-SB-SMPW-M
TJ36-CAIN-18(*)-(**)-SB-SMPW-M
TJ36-CAIN-316(*)-(**)-SB-SMPW-M
TJ36-CAIN-14(*)-(**)-SB-SMPW-M
Super
OMEGACLAD™
XL
1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
1038 (1900)
1149 (2100)
1204 (2200)
1204 (2200)
TJ36-CAXL-116(*)-(**)-SB-SMPW-M
TJ36-CAXL-18(*)-(**)-SB-SMPW-M
TJ36-CAXL-316(*)-(**)-SB-SMPW-M
TJ36-CAXL-14(*)-(**)-SB-SMPW-M
J
Iron-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
441 (825)
521 (970)
621 (1150)
721 (1330)
TJ36-ICSS-116(*)-(**)-SB-SMPW-M
TJ36-ICSS-18(*)-(**)-SB-SMPW-M
TJ36-ICSS-316(*)-(**)-SB-SMPW-M
TJ36-ICSS-14(*)-(**)-SB-SMPW-M
T
Copper-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
260 (500)
316 (600)
371 (700)
371 (700)
TJ36-CPSS-116(*)-(**)-SB-SMPW-M
TJ36-CPSS-18(*)-(**)-SB-SMPW-M
TJ36-CPSS-316(*)-(**)-SB-SMPW-M
TJ36-CPSS-14(*)-(**)-SB-SMPW-M
Notes: *Specify Junction: (G)rounded, (E)xposed or or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NN for CA in Model Number. See ordering examples below.

View the Thermocouple Accuracy and Color Code charts
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
Click to expand/minimize a list of what others bought with theTJ36-CASS-116G-6-SB-SMPW-M
TJ36-CASS-116G-6-SB-SMPW-M
AUD121.44
Availability: 6 weeks
 
TJ36 Type K Probe in 304 stainless steel, 1.5 mm ( 1/16 in.) dia., 150 mm (6 in.) in length; grounded tip; 1 m (40 in.) PFA lead wire with stainless steel overbraid; and miniature male connector.
Click to expand/minimize a list of what others bought with theTJ36-CASS-18U-6-SB-SMPW-M
TJ36-CASS-18U-6-SB-SMPW-M
AUD134.48
Availability: 1 week
 
TJ36-CASS-116G-6-SB-SMPW-M
  
TJ36-CAXL-18U-12-SB-SMPW-M
AUD145.69
Availability: 1 week
 
TJ36 Type K Probe in Super OMEGACLAD™ XL, 3 mm ( 1/8 in.) dia., 300 mm (12 in.) in length; ungrounded tip; 1 m (40 in.) PFA lead wire with stainless steel overbraid; and miniature male connector.
  
TJ36-ICSS-18U-6-SB-SMPW-M
AUD134.00
Availability: 6 weeks
 
TJ36 Type J Probe in 304 stainless steel, 3 mm ( 1/8 in.) dia., 150 mm (6 in.) in length; ungrounded tip; 1 m (40 in.) PFA lead wire with stainless steel overbraid; and miniature male connector.
  
TJ36-CAIN-316E-6-SB-SMPW-M
AUD129.00
Availability: 1 week
 
TJ36 Type K Probe in Inconel®, 4.5 mm (3/16 in.) dia., 150 mm (6 in.) in length; exposed tip; 1 m (40 in.) PFA lead wire with stainless steel overbraid; and miniature male connector.
  
TJ36-CPSS-116G-12-SB-SMPW-M
AUD126.00
Availability: 6 weeks
 
TJ36 Type T Probe in 304 stainless steel, 1.5 mm (1/16 in.) dia., 300 mm (12 in.) in length; grounded tip; 1 m (40 in.) PFA lead wire with stainless steel overbraid; and miniature male connector.
  
TJ36-CASS-14U-6-SB-SMPW-M
Consult Sales  
Availability: 
 
 
HEAVY duty transition joint probe, type K, 304 SS sheath, 1/4  inch Dia., ungrounded junction, 6 inch length with SMPW Connector & stainless steel braid wire
  
TJ36-CASS-116G-18-SB-SMPW-M
Consult Sales  
Availability: 
 
 
HEAVY duty transition joint probe, type K, 304 SS sheath, 1/16  inch Dia., grounded junction, 18 inch length with SMPW Connector & stainless steel braid wire
  
TJ36-CASS-18G-12-SB-SMPW-M
Consult Sales  
Availability: 
 
 
HEAVY duty transition joint probe, type K, 304 SS sheath, 1/8  inch Dia., grounded junction, 12 inch length with SMPW Connector & stainless steel braid wire
  
TJ36-CAIN-18U-6-SB-SMPW-M
Consult Sales  
Availability: 
 
 
HEAVY duty transition joint probe, type K, IN sheath, 1/8  inch Dia., ungrounded junction, 6 inch length with SMPW Connector & stainless steel braid wire
All amounts shown in AUD
Ordering Example: (1) TJ36-CAIN-316E-6-SB-SMPW-M TJ36 Type K Probe in Inconel®, 4.5 mm (3/16 in.) dia., 150 mm (6 in.) in length; exposed tip; 1 m (40 in.) PFA lead wire with stainless steel overbraid; and miniature male connector., AUD129.00

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Thermocouple Type select from:
CA for Type K
IC for Type J
CP for Type T
NN for Type N

(2) Sheath Material select from:
SS for 304 Stainless Steel
IN for Inconel®
XL for Super OMEGACLAD™ XL

(3) Probe Diameter select from:
116 for 1.5 mm (1/16 in.)
18 for 3 mm (1/8 in.)
316 for 4.5 mm (3/16 in.)
14 for 6 mm (1/4 in.)

(4) Junction Type select from:
G for Grounded
E for Exposed
U for Ungrounded

(5) Probe Length select from:
6 for 6 in. (150 mm)
12 for 12 in. (300 mm)
18 for 18 in. (450 mm)
Note: All combinations may not be valid, check spec sheet for valid part numbers.