4-IN-1 Air Velocity Meter - Anemometer, Hygrometer, Light Meter, Thermometer

HHF81

Air Flow Anemometer | HHF81

Air Flow Anemometer

AUD390.24 HHF81

CE
  • Simultaneous Readings of Air Velocity and Temperature or Humidity and Temperature
  • Exclusive Photo Diode and Color Correction Filter Light Sensor, Spectrum Meets C.I.E. Photopic
  • Standard Type K Thermocouple SMP Input Jack Suitable for All Types of K Probes
  • Lux/Feet-Candle Selectable by Pressing Button on the Front Panel
Anemometers & Wind Tunnels - View related products

Description

The HHF81 anemometer can measure air flow, humidity, temperature and light. The built-in microprocessor circuit assures excellent performance and accuracy. The HHF81 can track the maximum and minimum values along with current readings. The HHF81 displays the flowrate in your choice of knots, meters per second, kilometers per hour, miles per hour, or feet per minute.

The HHF81 relies upon a low-friction ball bearing mounted wheel design to provide high accuracy at high and low air velocity. The impeller provides excellent accuracy (±3 to 4%) and the ability to measure the slightest breeze (0.3 m/s). For temperature readings, the HHF81 has an internal thermistor or is compatible with any Type K thermocouple with SMP Male connector, and is accurate to ±1°C + 1% of reading. The humidity sensor measures to 95% relative using a high precision thin-film capacitance sensor with fast response to humidity changes. The Light measurement utilizes an exclusive photo diode and color correction filter light sensor.

SPECIFICATIONS
AIR VELOCITY
Measurement Range: 80 to 5910 ft/min, 0.4 to 30.0 m/s, 0.9 to 67.0 mph, 1.4 to 108.0 km/hr, 0.8 to 58.3 knots, 0.8 to 58.3 knots
Resolution: 1 ft/min, 0.1 m/s, 0.1 mph, 0.1 km/hr, 0.1 knots
Accuracy:
   ≤20 m/s: 3% FS
   >20 m/s: 4% FS
TEMPERATURE (Internal Thermistor)
Measurement Range: 0 to 50°C (32 to 122°F)
Resolution: 0.1°C/°F
Accuracy: ±1.2°C (±2.5°F)
Operational Temperature: 0 to 50°C (32 to 122°F)
TEMPERATURE (External Type K Thermocouple)
Measurement Range: -100 to 1300°C (-148 to 2372°F)
Resolution: 0.1°F/°C
Accuracy: ±(1% + 1°C) of rdg [±(1% + 2°F) of rdg]
HUMIDITY
Measurement Range: 10 to 95%
Resolution: 0.1%
Accuracy:
   <70% RH: ±4% of rdg
   ≥70% RH: ±(4% rdg + 1.2 % RH)
Operational Humidity Max.: 80% RH
LIGHT LUX
Measurement Range: 0 to 2200 Lux, 1800 to 20000 Lux, 0 to 204.0 Fc, 170 to 2000 Fc
Resolution: 1 Lux, 10 Lux, 0.1 Ft-cd, 1 Ft-cd
Accuracy: ±(5% rdg +8 dgt)
Overange Display: “----”
Battery: 9V (included)
Power Consumption: Approx. DC 6.2 mA
Weight: 160 g (0.4 lb) battery included
Dimensions: 156 x 60 x 33 mm (6.14 x 2.36 x 1.29")
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
Click to expand/minimize a list of what others bought with theHHF81
HHF81
AUD390.24
Availability: 1 week
 
4 in 1 environmental meter
Accessories
Click to expand/minimize a list of what others bought with theKHSS-18E-RSC-12
KHSS-18E-RSC-12
AUD119.86
Availability: 5 weeks
 
Type K thermocouple—exposed element for air
Click to expand/minimize a list of what others bought with theKTSS-HH
KTSS-HH
AUD99.03
Availability: 5 weeks
 
Type K thermocouple—grounded element for air or liquids
Click to expand/minimize a list of what others bought with the5SRTC-TT-K-24-36
5SRTC-TT-K-24-36
AUD155.80
Availability: 1 week
 
5 pk of K Thermocouples with connectors
  
SMPW-K-M
AUD6.14
Availability: 1 week
 
Type K SMP male connector with write on window
  
MN1604
Consult Sales  
Availability: 
 
 
replacement 9 V battery
All amounts shown in AUD
Note: Comes complete with operators manual and 9 V battery.
Ordering Example: (1) HHF81 5 digit multi parameter air flow meter, AUD390.24
We noticed you are from the US. Visit your local site for regional offers and live support.